Camera Installation
Accessory cable 5-conductor for Alarm In/Out (optional)
PoE power supply or PoE switch, if used for system power.
Cat5e or Cat6 Ethernet cable for digital video and/or PoE for system power
Coaxial RG59U cables (BNC connector at the camera end) for analog video
Camera grounding strap, camera mount, electrical hardware, connectors, and tools
1.3.4 Camera Placement
For installations with multiple FB-Series ID cameras with on-board video analytics, the fields of view
of cameras should overlap in order to remove all dead zones in which a camera cannot see a target
“head to toe”. The camera’s on-board analytics must be calibrated to detect targets. Refer to Video
Analytics Setup—FB-Series ID Only, pg. 37.
Install the camera at a height of approximately 4 m (13 ft) or more.
Typically direct the camera towards the ground with a tilt angle α within a range of 45° to 60°
while ensuring the field of view includes as little of the skyline as possible.
Ensure that cameras are mounted on stable mounts with minimal vibrations and maximal
resistance to wind.
The tilt angle (
α) is the angle between vertical and the center of the camera field of view.
1.3.5 Mounting Accessories
The following mounting accessories are available from FLIR Systems, Inc. for installing the FB-
Series camera. For more information on available options, contact your FLIR sales representative to
request details on where to get the accessories you need.
α
4 m
Wall Mount Junction Box CB-WLBX-62
Pole Mount Junction Box CB-PLBX-62