Certifications 2
赛尔特电池科技(中山)有限公司
Celltech (Zhongshan) Ltd.
Handling
Advice on safe handling
Avoid short circuiting the cell. Avoid mechanical damage of the cell. Do not open or disassemble. Advice on
protection against fire and explosion
Keep away from open flames, hot surfaces and sources of ignition.
Storage
Requirements for storage rooms and vessels
Storage at room temperature (approx. 20°C) at humidity approx. 60% of the nominal capacity.
Keep in closed original container.
8. Exposure controls/personal protection Exposure limit values Exposure limits
Ingredient Risk Codes Safety Description Hazard Exposure Controls/Personal Protection
Lithium Cobalt oxide
R22;R43;
R50/53
S24; S37; S60; S61
Xn(Harmful)
(Dangerous for the environment)
0.1 mg/m3 (TWA)
Manganese (VI)
oxide
R20/22 S25 Xn(Harmful)
Airborne Exposure Limits:
- OSHA Permissible Exposure Limit (PEL):
5 mg/m3 Ceiling for manganese compounds as Mn
- ACGIH Threshold Limit Value (TLV):
0.2 mg/m3 (TWA) for manganese, elemental and
inorganic compounds as Mn
Nickel oxide
R43,R49
R53,
R36/37/38
S45,S53,S61 T(Toxic)
Airborne Exposure Limits:
For Nickel, Metal and Insoluble Compounds, as Ni:
- OSHA Permissible Exposure Limits (PEL) -
1 mg/m3 (TWA).
For Nickel, Elemental / Metal:
- ACGIH Threshold Limit Value (TLV) -
1.5 mg/m3 (TWA), A5 - Not suspected as a human
carcinogen.
For Nickel, Insoluble Compounds, as Ni:
- ACGIH Threshold Limit Value (TLV) -
0.2 mg/m3 (TWA), A1 - Confirmed human carcinogen
Carbon
R36/37
R20, R10
S22; S24/25
F (Highly Flammable)
Xn (Harmful)
Xi(Irritant)
Airborne Exposure Limits:
- OSHA Permissible Exposure Limits (PELs):
activated carbon (graphite, synthetic):
Total particulate = 15 mg/m3
Aluminium
foil
R17,R15
R36/38
R10,R67,
R65,R62
R51/53,
R48/20,
R38,R11
S7/8,S43,S26,S62,
S61, S36/37, S33, S29,
S16, S9
F(Highly Flammable)
Xn(Harmful)
Xi(Irritant)
Airborne Exposure Limits:
-OSHA Permissible Exposure Limit (PEL):
15 mg/m3 (TWA) total dust and 5 mg/m3(TWA)
Repairable fraction for Aluminum metal as Al
-ACGIH Threshold Limit Value (TLV):
10 mg/m3 (TWA) Aluminum metal dusts
Copper foil
R11 R36
R37 R38
S5, S26, S16, S61,
S36/37
F(Highly Flammable)
N(Dangerous for the environment)
Xn(Harmful)
Xi(Irritant)
Copper Dust and Mists, as Cu:
- OSHA Permissible Exposure Limit (PEL) -
1 mg/m3 (TWA)
- ACGIH Threshold Limit Value (TLV) -
1 mg/m3 (TWA)
Copper Fume:
- OSHA Permissible Exposure Limit (PEL)
0.1 mg/m3 (TWA)
- ACGIH Threshold Limit Value (TLV) -
0.2 mg/m3 (TWA)
Polyvinylide ne
fluoride(PVdF)
S22;S24/25