Datasheet

Visit www.ir.com
FULL PRODUCT
WARRANTY*
DETECTOR
WARRANTY*
FULL PRODUCT
WARRANTY
DETECTOR
WARRANTY
* After product registration on www.flir.com
38
FLIR P660
Technical specications
Imaging Performance
IR resolution 640 x 480 pixels
Spectral range 7.5 - 13 µm
Image frequency 30 Hz
Focus Automatic (one shot or follow the laserspot) or manual (electric or on the lens)
Focal Plane Array (FPA) Uncooled microbolometer
Field of View (FOV) / minimum focus distance 24° x 18° / 0.3 m
12° x 9° / 1.2 m
45° x 34° / 0.2 m
lens needs to be specied when ordering
Spatial resolution 0.65 mrad for 24°lens
0.33 mrad for 12° lens
1.3 mrad for 45° lens
Thermal sensitivity 30 mK at 30°C
Digital zoom 1-8x continuous, including pan function
Image presentation
Display Built-in Widescreen, 5.6” color LCD, 1024 x 600 pixels
Viewnder Built-in, tiltable LCD, 800 x 600 pixels
Automatic contrast optimization Adjustable DDE
Automatic image adjustments Continuous/manual; linear or histogram based
Manual image adjustments Level/span/max./min.
Image modes IR image, Visual image, Thumbnail gallery, Thermal Fusion, Picture in Picture
Reference image Shown together with live IR image
Thermal Fusion
IR image shown above, below or within temperature interval on the visual image (with 24° lens only)
Picture in Picture Resizeable and moveable IR area on visual image (with 24° lens only)
Measurement
Temperature range -40°C to +500°C (optional up to +2000°C)
Accuracy ± 1°C or ± 1% of reading (restricted range)
± 2°C or ± 2% of reading
Measurement analysis
Isotherm 2 with above/below interval
Spotmeter 10
Area 5 boxes or circles
with Max./Min./Average
Measurement function alarm
Audible/visual alarms (above/below) on any selected measurement function
Prole 1 live line, horizontal or vertical
Difference temperature Delta temperature between measurement functions or reference temperature
Automatic hot / cold detection Max./Min. temp. value and position shown within box, circle or on a line
Reference temperature Manually set or captured from any measurement function
Emissivity correction Variable from 0.01 to 1.0 or selected from editable list of materials
Measurement corrections Reected temperature, optics transmission, atmospheric transmission and external optics
External optics/windows correction
Automatic, based on inputs of optics/window transmission and temperature
Humidity alarm
1 humidity alarm, incl. dew point alarm
Insulation alarm
1 insulation alarm