CP-6408-31-I-Quick-Install-Guide

CP-6408-31-I QIG Rev 120
June 2021
This document does not contain any export-controlled information.
3.4 Connect the Camera
Connectors
Connector
Connection
DEFAULT
To reset factory defaults at any time, press the Default
button for at least 20 seconds.
LAN
Attach a Cat 5e or Cat 6 cable from the network switch
to the RJ45 connector for a 10/100/1000 Mbps Ethernet
and PoE connection. If using PoE, use a FLIR CP-POE-
4P-60W-xx injector or a switch that supports Universal
PoE 60W 4 pair forced mode. For more information
about compatible injectors and recommended switches,
contact Teledyne FLIR support. Verify that the LAN
connector LEDs are steady green and flashing yellow.
AC24V
(DC24V) IN
If using a 24 VAC or 24 VDC power supply, connect it to
the three-pin power terminal block plug according to the
pin assignment shown.
14-pin
terminal
block
Attach wires from external alarm and audio I/O devices
to the 14-pin alarm/audio I/O terminal block plug
according to the pin assignment shown.
3-Pin Power
Terminal Block
Pin
24 VAC
24 VDC
1
L (Live; white; positive)
Pins 1 and 3
(polarity N/A)
2
Ground (Earth)
3
N (Neutral; black; negative)