CP-6408-31-I-Quick-Install-Guide
Table Of Contents
CP-6408-31-I QIG Rev 120
June 2021
This document does not contain any export-controlled information.
3.4 Connect the Camera
Connectors
Connector
Connection
1
DEFAULT
To reset factory defaults at any time, press the Default
button for at least 20 seconds.
2
LAN
Attach a Cat 5e or Cat 6 cable from the network switch
to the RJ45 connector for a 10/100/1000 Mbps Ethernet
and PoE connection. If using PoE, use a FLIR CP-POE-
4P-60W-xx injector or a switch that supports Universal
PoE 60W 4 pair forced mode. For more information
about compatible injectors and recommended switches,
contact Teledyne FLIR support. Verify that the LAN
connector LEDs are steady green and flashing yellow.
3
AC24V
(DC24V) IN
If using a 24 VAC or 24 VDC power supply, connect it to
the three-pin power terminal block plug according to the
pin assignment shown.
4
14-pin
terminal
block
Attach wires from external alarm and audio I/O devices
to the 14-pin alarm/audio I/O terminal block plug
according to the pin assignment shown.
3-Pin Power
Terminal Block
Pin
24 VAC
24 VDC
1
L (Live; white; positive)
Pins 1 and 3
(polarity N/A)
2
Ground (Earth)
3
N (Neutral; black; negative)