Using the System Menu
EVENT/SENSOR
Configure HDD events, alarm input/
output, buzzer, and email
notifications.
HDD EVENT
Use the HDD Event menu to allow the system
to monitor the internal hard disk.
NOTE: If more than one HDD is installed the
system, the system will treat the hard drives as
one HDD
.
To set HDD event alarms:
1. Select HDD EVENT and press ENTER.
2. Under SMART ALARM, select ON/OFF. If
ON, an alarm will sound if the system
detects errors with the internal HDD.
NOTE: "SMART"=Self Monitoring and
Recording Technology.
3. Under CHECK INTERVAL, select 1 HOUR
(default), ~ 24 HOUR. This sets the
frequency that the system will check the
internal HDD for errors.
4. Under DISK FULL EVENT, select ON/OFF.
If ON, the system will sound an alarm
when the internal HDD is full.
5. Select APPLY and press ENTER to save
your settings or select CANCEL to restore
defaults.
6. Select CLOSE and press ENTER to exit.
ALARM INPUT
Use the Alarm Input menu to configure
external alarm devices (i.e. a door or window
sensor).
NOTE: Make sure you have properly
connected an external alarm device to the
alarm block on the rear panel of the system
prior to configure alarm settings. For more
details,
see “Appendix F: Connecting Motion
/ Alarm Devices” on page 103.
To configure alarm inputs:
1. Select ALARM INPUT and press ENTER.
2. Under OPERATION, select ENABLE or
DISABLE.
3. Under TYPE, select N / O (normally open)
or N / C (normally closed), depending on
the status of your external alarm device.
4. OPTIONAL: Under TEXT, select a channel
and press ENTER to open the Virtual
Keyboard and enter a name for the Alarm.
5. Repeats steps 2~4 for remaining
channels.
6. Select APPLY and press ENTER to save
your settings or select CANCEL to restore
defaults.
7. Select CLOSE and press ENTER to exit.
Figure 23.0 HDD Event menu
Figure 23.1 Alarm Input menu