Product Manual

FLIRDM92USERGUIDEDocumentIdentifier:DM92enUS_AB
18
5.11.5Frequencymode(ACVandACAonly)
InFrequencymode,thefrequencyisdisplayedinthemaindisplayandtheperiodisdisplayed
inthesecondarydisplay.FrequencymodeisavailablewhenmeasuringACvoltageorcurrent.

1. Select andenableFrequencymodeasdescribedinsection5.11.1Selectingthemode.
5.11.6Relativemode
In Relative mode, the difference between the current reading and a stored reference value is
displayed in the main display. The reference value is displayed in the secondary display.
1. Select andenableRelativemodeasdescribedinsection5.11.1Selectingthemode.
5.11.7dBmMode(ACVonly)
Thedecibel(dB)isalogarithmicunitthatexpressesthemagnitudeofaphysicalquantity
relativetoaspecifiedorimpliedreferencelevel.IndBmmode,themeterdisplaysAC
voltagemeasurementsindBordBmonthesecondarydisplay.
dBanddBmaredefinedasfollows:
dB=20
log(V
AC
/1).
dBm=20log(V
AC
/0.7746).
1. Select andenabledBmmodeasdescribedinsection5.11.1,Selectingthemode.
2. Pressthethe
or buttontotogglebetweenthedisplayofdBanddBm.
5.11.8ManualDataRecordingMode
Themeterhas99memorylocationsforthestorageofmeasurementdata.
1. Select andenableManualDataRecordingmode
asdescribedinsection5.11.1
Selectingthemode.
2. Pressthe
or buttontocyclethroughthemodeoptions:SAVE,LOAD,andCLEAR
shownonthesecondarydisplay.
3. Pressthe
buttontoactivatethedisplayedoption:
SAVE:Thedataonthemaindisplayissavedtoamemorylocationshownbythe
indicatorintheupperpartofthedisplay.
LOAD:Thedatastoredinthememorylocationshownbythe indicatoris
displayed.Usethe
or buttontochangethememorylocation.Pressthe
buttontoexittheloadfunction.
CLEAR:Thedatainallmemorylocationsiserased.