Installation Manual

Table Of Contents
427-0089-00-12 Version 160 March 2019 65
This document does not contain any export-controlled information.
Advanced Configuration
Alarm Rule Examples: The following examples show rules that control actions from alarms that
are internal to the camera (rather than coming from another source on the network). The first three
lines and the fifth line of these rules is always the same for the alarms coming from the FC-Series ID
camera itself, and only the source type changes (Video Analytics or GPIO Input).
Video Analytics Alarm to Email: Shown at the right is an
example of an alarm rule that causes an email notification
(with a snapshot image) to be sent when a motion alarm
occurs in Analytics Region 0 or Region 1 (Area or Tripwire).
Refer to Creating Analytics Regions, pg. 53).
The Alarm Source Device Type is set to Video Analytics
with Alarm Id set to “1” corresponding to Analytics Area 1.
The Send Notification action uses a Msg System and a
Notification List that are set up in the Services menu (refer to
Msg Systems, pg. 31). The email includes alarm information,
including the Area ID and if it is a human or vehicle alarm.
When an email is sent, the Alarm Manager can attach a
snapshot from the camera to the email. In Attach Image File,
All Non Radiometric is selected for the type of image.
FC-Series ID Options:
Video Analytics and
GPIO
Indicates the
alarm comes
from the camera
itself, rather than
another device
on the network.
Enable each alarm rule