Product Manual
FLIRIM75USERGUIDEDocumentIdentifier:IM75‐en‐US_AA
22
InternalMemory (99)storagelocations
OperatingTemperature 32to122°F(0to50°C)
StorageTemperature‐4to140°F(‐20to60°C)
OperatingHumidity
Max80%upto95°F(35°C)decreasinglinearlyto60%at
113°F(45°C)
StorageHumidity 80%maximum
Indooruseonly
Altitude 6561’(2000m)
Dimensions 3.7”x8.1”x2.0”(95mmx207mmx52mm)
Weight 1.4lb(630g),includingbatteries
AgencyApprovals FCCClassB,CE,UL/CSA
7.2ElectricalRangeSpecifications
Note:Accuracyisstatedat65°Fto83°F(18°Cto28°Candlessthan75%RH)
Function Range Resolution AccuracyofReading
DCVoltage
1000.0V 0.1V ±(0.1%+5digits)
ACVoltage
1000.0V 0.1V 50Hz–60Hz±(1.5%+5digits);
61Hz–500Hz±(2.0%+5digits);
VFDACVoltage
1000.0V 0.1V 50Hz–60Hz±(1.5%+5digits);
61Hz–500Hz±(5.0%+5digits);
Notes: 1.Measurementstart‐voltage:</‐50V(add20digitsforaccuracy)
2.VFD/LPFCutoff=800Hz(‐3dBpoint)
3.InputImpedance3MΩ//lessthan100pF
Function Range Resolution AccuracyofReading
Earth‐Bond
Resistance
40.00Ω 0.01Ω ±(1.5%+5digits)*
400.0Ω
4000Ω
40.00kΩ
0.1Ω
1Ω
0.01KΩ
±(1.5%+3digits)
Notes: 1.*≤1.00Ωadd3digits.
2.OpenCircuitTestVoltage:>4.0V,<8V
3.ShortCircuitCurrent≥
200.0mA
4.LiveCircuitDetectionifGreaterthanorequalto2V@AC/DCInputstestinhibited