Product Manual
FLIRIM75USERGUIDEDocumentIdentifier:IM75‐en‐US_AA
23
Function Range Resolution AccuracyofReading
Continuity 400.0Ω 0.1Ω ±(0.5%+2digits)
Diode 2.000V 0.001V ±(1.5%+2digits)
Notes:
Continuity:Built‐inbuzzersoundswhenmeasuredresistancethresholdismet(adjustablefrom10Ωto50Ω,
defaultis30Ω).
ContinuityMAXTestCurrent:1mA
ContinuityMAXOpenCircuitVoltage>3.0V
DiodeMAXTestCurrent:1mA
DiodeMAXOpenCircuitVoltage:3.0V
OverloadProtection:1000VACrmsorDC
Function Range Resolution AccuracyofReading
Capacitance
1000µF 1µF ±(1.2%+2digits)
10.00mF 0.01mF ±(1.2%+20digits)
Notes:1.OverloadProtection:1000VACrmsorDC
Function Range Resolution AccuracyofReading
Frequency(ACV)
400.0Hz 0.1Hz
±5digits
4.000kHz 0.001kHz ±5digits
40.00kHz 0.01kHz ±5digits