Operation Manual
TM
USER GUIDE 8
LOCK SPAN
Ordinarily, the camera uses an Automatic Gain Control (AGC)
process to automatically adjust the image based on the range of
temperatures that are in the scene. The camera detects the range
or span of temperatures, and maps the temperatures to colors in
the color palette dynamically. As a result, the color of an object at a
certain temperature can vary, depending on the other temperatures
in the scene. When measuring temperatures with the Spot Meter,
sometimes it may be desirable to temporarily lock the range of
temperatures to a certain range, so that it is possible to compare
multiple images taken at dierent times and of dierent scenes. Tap
the Lock Span button to set the span or range of temperatures based
on the current image.
OPTIMIZATION SLIDER CONTROL
Observe the right edge of the faucet below. The image on the left
shows the lines of the visible image oset from the thermal image,
and the image on the right shows the visible image aligned with
the thermal. Tap and hold anywhere on the screen while in Camera
Mode to activate the slider control, then adjust the alignment by
sliding the control. To exit the slider control, simply tap anywhere on
the screen.
OPTIMIZATION SLIDEROFFSET ALIGNED