User Guide

427-0075-01-12 Revision 140 October 2019 4
This document does not contain any export-controlled information.
PT-Series HD Camera Installation
The PT-Series HD pan/tilt thermal security camera for medium- to long-range applications can be used
with traditional analog video installations or IP video networks. It incorporates a high-sensitivity thermal
camera with a choice of lenses and a long-range daylight camera all within a precision pan/tilt platform.
The PT-602CZ HD pairs a cooled mid-wave focal plane array (FPA) thermal detector with the daylight
camera.
This manual describes the installation of the PT-Series HD cameras. If help is needed during the
installation process, please refer to for support. All
installers and integrators are encouraged to take advantage of the training offered by FLIR; visit
for more information.
This manual includes the following topics:
Installation overview
Mounting the camera and its components
Connecting the electronics
Bench testing the camera
Configuration and operation of the camera
Camera specifications
For safety, and to achieve the highest levels of performance from the camera system, follow the
warnings and cautions in this manual when handling and operating the camera system.
(ICD)
(FLIR Doc # 427-0075-XX-19)—available from the FLIR website, provides further details regarding
mechanical dimensions and mounting for the PT-Series HD camera.
If mounting the camera on a pole, tower or any elevated location, use industry standard safe
practices to avoid injuries.
Except as described in this manual, do not open the camera for any reason. Disassembly of the
camera (including removal of the cover) can cause permanent damage and will void the warranty.
Be careful not to leave fingerprints on the camera’s infrared optics.
The camera requires a power supply of 24 Volts nominal. Operating the camera outside of the
specified input voltage range or the specified operating temperature range can cause permanent
damage.