Technical data26
26.12 FLIR T1030sc 45°
P/N: 72501-0203
Rev.: 36738
General description
The FLIR T1030sc is designed for the expert requiring the highest performance and the latest technology
available. The camera combines excellent ergonomics and feature-rich flexibility with superior image
quality at an infrared resolution of 1024 × 768 pixels. High accuracy and sensitivity together with radio-
metric recording and streaming options make the FLIR T1030sc well suited for advanced research and
development.
Benefits:
• Tailor made for research and development: The FLIR T1030sc has high accuracy and high sensitivity,
to accurately measure the smallest temperature differences. With real-time radiometric recording, it is
possible to capture fast events on the camera’s SD card for further analysis by the supplied analysis
software.
• Flexible and feature rich: A wide variety of measuring and analysis functions make the FLIR T1030sc
flexible for your every need. Two programmable buttons provide easy access to favorite functions.
• Highest performance with the latest technology: The FLIR T1030sc is equipped with the innovative
Multi Spectral Dynamic Imaging (MSX) feature, which produces an image richer in detail than ever be-
fore. With its continuous autofocus, the FLIR T1030sc is a fully automatic infrared camera.
• Support for UltraMax: When enabling UltraMax in the camera, the resolution of images can be sub-
stantially enhanced when importing the images into FLIR Tools.
Imaging and optical data
IR resolution 1024 × 768 pixels
MSX resolution
1024 × 768 pixels
UltraMax Yes
Thermal sensitivity/NETD <20 mK @ +30°C (+86°F)
Field of view (FOV)
45° × 34°
Minimum IR focus distance 0.2 m (0.66 ft.)
Minimum IR–visual alignment distance 0.5 m (1.64 ft.)
Focal length 21.2 mm (0.83 in.)
Spatial resolution (IFOV) 0.80 mrad
Lens identification Automatic
F-number 1.1
Image frequency 30 Hz
Focus
One shot or manual
Digital zoom 1–8× continuous
Digital image enhancement Adaptive digital noise reduction
Detector data
Detector type Focal plane array (FPA), uncooled microbolometer
Spectral range
7.5–14 µm
Detector pitch 17 µm
Time constant < 10 ms
Image presentation
Display Built-in touch screen, 4.3 in. wide screen LCD, 800
× 480 pixels
Display type Capacitive touch screen