Operation Manual

Technical data26
26.12 FLIR T1030sc 45°
P/N: 72501-0203
Rev.: 36738
General description
The FLIR T1030sc is designed for the expert requiring the highest performance and the latest technology
available. The camera combines excellent ergonomics and feature-rich flexibility with superior image
quality at an infrared resolution of 1024 × 768 pixels. High accuracy and sensitivity together with radio-
metric recording and streaming options make the FLIR T1030sc well suited for advanced research and
development.
Benefits:
Tailor made for research and development: The FLIR T1030sc has high accuracy and high sensitivity,
to accurately measure the smallest temperature differences. With real-time radiometric recording, it is
possible to capture fast events on the camera’s SD card for further analysis by the supplied analysis
software.
Flexible and feature rich: A wide variety of measuring and analysis functions make the FLIR T1030sc
flexible for your every need. Two programmable buttons provide easy access to favorite functions.
Highest performance with the latest technology: The FLIR T1030sc is equipped with the innovative
Multi Spectral Dynamic Imaging (MSX) feature, which produces an image richer in detail than ever be-
fore. With its continuous autofocus, the FLIR T1030sc is a fully automatic infrared camera.
Support for UltraMax: When enabling UltraMax in the camera, the resolution of images can be sub-
stantially enhanced when importing the images into FLIR Tools.
Imaging and optical data
IR resolution 1024 × 768 pixels
MSX resolution
1024 × 768 pixels
UltraMax Yes
Thermal sensitivity/NETD <20 mK @ +30°C (+86°F)
Field of view (FOV)
45° × 34°
Minimum IR focus distance 0.2 m (0.66 ft.)
Minimum IR–visual alignment distance 0.5 m (1.64 ft.)
Focal length 21.2 mm (0.83 in.)
Spatial resolution (IFOV) 0.80 mrad
Lens identification Automatic
F-number 1.1
Image frequency 30 Hz
Focus
One shot or manual
Digital zoom 1–8× continuous
Digital image enhancement Adaptive digital noise reduction
Detector data
Detector type Focal plane array (FPA), uncooled microbolometer
Spectral range
7.5–14 µm
Detector pitch 17 µm
Time constant < 10 ms
Image presentation
Display Built-in touch screen, 4.3 in. wide screen LCD, 800
× 480 pixels
Display type Capacitive touch screen
#T559954; r. AL/37426/37426; en-US