Specification

TECHNICAL SUBMITTAL DATA SHEET
Water Tank Leak Detection & Automatic Shut-Off System
Job Name: _____________________________________________
Engineer: ______________________________________________
Contractor: _____________________________________________
Contractor P.O.: ________________________________________
Job Location: ___________________________________________
Engineer Approval: ______________________________________
Contractor Approval: ____________________________________
Representative: _________________________________________
MODEL RS-094
Patent #6,035,699
Receiver Box / Actuator
Power
Supply
Shut-Off
Valve
NO/C/NC
Dry Contacts
Water Sensor
203-488-2684 or 888-771-4929
info@RelianceDetection.com
www.RelianceDetection.com
TYPICAL INSTALLATIONS
INCLUDE:
Common-risk housing – condos
and apartments
Commercial break rooms
New and retrot construction
Vacation homes and other
unattended properties
HIGHLY RECOMMENDED FOR:
Multi-residential complexes
Commercial oce buildings
Any facility with a history of insurance
claims for water damage
FEATURES:
Full port valve sizes 1/2” to 1-1/4” dia.
Reusable and testable
Easy reset button
Snap-t actuator allows for manual
operation of the valve
Plugs into a standard 120V AC outlet
Audible alarm (83 dB)
N/O and N/C dry contacts
Factory pre-wired
MODIFIED KIT CONFIGURATIONS:
RS-094-MK6 for Plenum Spaces
RS-094-MK1 with Rope Sensor for
Low-Prole Tanks
RS-094-MK4 with Electrical Plug Interrupter
RS-094-MK5 Kit with Gas Flow Interrupter
RS-094-MK7 Kit with Gas Interface Cable
APPLICATION CONSIDERATIONS:
The RS-094 system is designed to prevent damage caused by undetected plumbing leak
from a water tank. The full port valve installs on the cold water inlet line to the water
heater, and the snap-t actuator attaches directly to the valve mounting pad. A leak
detection sensor is placed in the pan or on the oor under the tank, typically under the
pressure relief valve or in a similar area where water from a leak is likely to accumulate.
INSTALLATION OVERVIEW:
The RS-094 plugs into a standard 120V AC wall outlet. Components come
pre-wired. The system can be performance tested anytime; it is resettable via reset
button on actuator. Suitable for new construction or retrot, gas-powered or electric
tanks, conventional or tankless systems. Optional dry contact connections (NO/C/NC) are
available for fault notication to existing security panel or BMS.
Emergency manual operation of the valve is accomplished by removing the snap-t
actuator and manually changing the valve to open or closed. In the event of a power
failure, the valve will remain in position (either open or closed).