Warranty

© 2008 OJ Electronics A/S - ® The OJ trademark is a registred trademark belonging to OJ Electronics A/S © 2008 OJ Electronics A/S
Press the pin button for 3 secs. and the thermostat returns to factory settings. Time,
d
ay and scale for time (12h, 24h) and temperature (˚F, ˚C) read-out are also reset and
m
ust be set according to “Setting the thermostat into operation”.
5
. Reset to factory setting
4-event time and temperature
D
ay 1-5
06:00 a.m.
T
ime
U
CCG-9991
w/floor sensor
U
CCG-9999
w/room sensor
0
8:00 a.m.
4
:00 p.m.
1
0:00 p.m.
08:00 a.m.
1
1:00 p.m.
5:2
4-event sequence
131˚F / 41˚F OFF/OFF OFF/OFF 82˚F / 59˚F
12 H / ˚F
ON
Hi-Low temp.
Scale
Adaptive control
Day 6-7
77˚F / 25˚C
6
8˚F / 20˚C
6
8˚F / 20˚C
5
9˚F / 15˚C
7
7˚F / 25˚C
7
0˚F / 21˚C
6
8˚F / 20˚C
59˚F / 15˚C
77˚F / 25˚C
7
0˚F / 21˚C
6
8˚F / 20˚C
5
9˚F / 15˚C
U
CDG-9999
w/dual sensor
6
8˚F / 20˚C
5
9˚F / 15˚C
7
0˚F / 21˚C
59˚F / 15˚C
7
0˚F / 21˚C
5
9˚F / 15˚C
6. Failure codes
E0 = Internal failure, replace thermostat
E1 = Built-in sensor short-circuit or disconnected,
replace thermostat
E2 = External sensor short-circuit or disconnected
7. Technical data
Supply: . . . . . . . . . . . . . . . . . 120/240V AC 50/60 Hz
Load: . . . . . . . . . . . . 15A maximum (resistive load)
Power: . . . . . . . . . . . . . . . . . . . 1.800 W at 120V AC
3.600 W at 240V AC
GFCI: . . . . . . . . . . . . . . . . . . . . . . . . 5 mA trip level
Temperature range: . . . . +5 to +40°C, +40 to +104˚F
Amb. Temperature range:
Thermostat: . . . . . . . . . . . 0 to +40°C, +32 to +104˚F
GFCI: . . . . . . . . . . . . . -35 to +65°C, -31 to +149˚F
OJ ELECTRONICS A/S
Stenager 13B · DK-6400 Sønderborg
Tel. +45 73 12 13 14 · Fax +45 73 12 13 13
oj@oj.dk · www.oj.dk
Factory settings
4