Instructions / Assembly

Fill strainer housing with water to suction p ipe level. NEVER OPERATE THE PUMP WITHOUT WATER.
Water ac ts as a coolant and lubricant for the mechanical shaft sea l.
WARNING
If pump is being pressure tested (40 PSI MAXIMUM), be sure pressure has been released,
using the filter manual air relief valve, before removi ng strainer cover.
CAUTION
NEVER run pump dry. Running pump dry may damage seals, causing leakage, flooding, a nd
voids warranty. Fill strainer housing with wate
r before starting motor.
ATTENTION
Do NOT add chemicals to pool/spa system directly in front of pump suction. Adding
undiluted chemicals may damage pump and voids warranty.
ATTENTION
Before removing strainer cover:
1. STOP PUMP before proceeding.
2. CLOSE VALVES in suction and outlet pipes.
3. RELEASE ALL PRESSURE from pump and piping system using filter manual air relief valve. See filter
owner’s manual for more de tail.
Priming Pump
CAUTION
All suction and discharge valves MUST b e OPEN, as well as filter air relief va lve (if available)
on filter, when starting the circulating pump syste m. Failure to do so could r esult in severe personal injury.
Release all pressure from filter, pump, and piping system. See filter owner’s manual.
If water source is higher than the pump, pump will p rime itself when suction and outlet valves are opened.
If water source is lower than the pump, unscrew and remove strainer c over; fill strainer housing with
water.
Clean a nd lubricate strainer cover O-ring with high quality O-ring lubricant each time it is removed. Inspect
O-ring and re -install on strainer cover.
Replace strainer cover on strainer housing; turn clockwise to tighten cover.
NOTE - Tighten strainer cover by hand only (no wrenches).
Turn on power and wait for pump to prime, which may take up to five (5) minutes. Priming time will d epend on
vertical length of suction lift and horizontal length of suction pipe. If p
ump does NOT prime within five minutes,
stop motor and determine cause. Be sure all suction and discharge valves are open when pump is running. See
Troubleshootin g Guide.
ATTENTION
Wait five (5 ) seconds before re-starting pump. Failure to do so may cause reverse rotation
of motor and consequent serious pump damage.
Close filter manual air relief valve after pump is primed.
Maintenance
Clean strainer basket regularly. Do NOT strike basket to clean. Inspect strainer cover gasket regularly and
page 8