Data Acquisition Where you need it When you need it How you need it • • • • • • Accurate Flexible Easy-to-use Portable Networked Expandable to thousands of channels
Fluke data acquisition solutions adapt to your needs Get the data you want, where, how and when you want it. Fluke gives you a broad choice in how you collect and transfer data for process monitoring and laboratory test systems. You can choose a stationary or portable system. Transfer data to internal memory, to a removable memory card, or to your PC. Choose a standalone or distributed networked units. And you can expand your system from 20 to more than 2,000 channels.
The Fluke 2680 Series: Precise and versatile standalone or networked data acquisition The Fluke 2680 Series delivers the precision necessary for meticulous lab work along with the rugged flexibility to meet the ever changing needs of industrial applications. Run one standalone data logging system with 20 to 120 universal channels or connect several networked data acquisition systems to serve 2,000+ channels on your LAN.
2638A Hydra Series III Data Acquisition System The Fluke 2638A Hydra Series III: Key features • DC accuracy of 0.0024 % • Thermocouple accuracy of 0.5 °C • Up to 66 universal differential isolated inputs • On-screen color trend graphing of up to four channels at a time • Easy-to-use menu system for setup and data management • Multi-channel real-time data display • Input types: ac V, dc V, ac I, dc I, thermocouple, PRT (2, 3, 4 w), thermistor, resistance (2-4 w), frequency • 6.
Expandable channel capacity Universal input connector The 2638A incorporates the Fluke Universal Input Connector to bring more accuracy to thermocouple measurements than most other instruments in its class. The Universal Input Connector supports 14 worldwide thermocouple types. Temperaturefocused menu selections make the 2638A especially suitable for temperature validation applications.
Ordering information 2638A/60 Data Acquisition Unit/DMM: 60 universal channels (includes 3 relay boards, 2638A-RLY and 3 2638A-100 connectors 2638A/40 Data Acquisition Unit/DMM: 40 universal channels (includes 2 relay boards, 2638A-RLY and two 2638A-100 connectors 2638A/20 Data Acquisition Unit/DMM: 20 universal channels (includes one relay board, 2638A-RLY and one 2638A-100 connector Power selection: Specify 100 V, 120 V, 220 V, 240 V power when ordering (power setting may be changed by the end user) Each
2638A Hydra Series III specifications General specifications Mains voltage 100 V Setting: 90 V to 110 V 120 V Setting: 108 V to 132 V 220 V Setting: 198 V to 242 V 240 V Setting: 216 V to 264 V Memory Trigger Scan data RAM: 1 Mb Data flash memory: 10 Mb Setup flash memory: 10 Mb Scan rate 36 VA peak (24 W average) Fast: 46 channels per second max (dc) Medium: 17 channels per second Slow: 3 channels per second Display resolution: 4.5 to 6.
2680 Series Top precision and scalability for standalone or networked data acquisition 2686A Data Logging System Key features • 120 channel capacity chassis designed for small- and largescale precision data acquisition applications. • User-scalability from 20 to 120 universal analog input channels, which can include digital input/output and alarm contact outputs in a single chassis.
Fluke 2680 Series chassis and module selection chart Chassis On board memory PC interface DIO/chassis 2680A Analog channels/ chassis 120 none Ethernet 2686A 120 Ethernet Module Readings/ sec (max) 1000 100 N/A ATA Flash to 1 GB Channels/type 20 DIO + 8 relay DPST relays 20 DIO + 8 relay DPST relays Basic TC accuracy (type K) 0.8 °C 0.4 °C N/A 2680A-FAI 2680A-PAI 2680A-DIO Max voltage/ accuracy 20/universal analog 50/0.02 % 20/universal analog 150/300/0.
Model 2680A-PAI Module Input Range DC Volts 90 mV to 150/300 V AC Volts2 300 mV to 150/300 V Resistance 300 Ω to 3 MΩ Frequency 15 Hz to 1 MHz RTD (Pt100) -200 °C to 600 °C Thermocouples J -100 °C to 760 °C K -100 °C to 1372 °C T -100 °C to 400 °C Other Thermocouple types R, S, B, C, E, Resolution 0.3 mV to 1 mV 10 mV to 100 mV 1 mΩ to 10 Ω 0.01 Hz to 100 Hz 0.003 °C Accuracy (3-Sigma)1 0.01 % 0.3 % 0.015 % 0.05 % 0.06 °C 0.02 °C 0.02 °C 0.02 °C N, L, U 0.35 °C 0.4 °C 0.
2680 Series specifications • U niversal input module: Connect 20 analog inputs or virtually any sensor type without external signal conditioning • 2680A Series interfacing: Ethernet; uses TCP/IP protocol via RJ45 connector, Cat 5. RS-232 input for calibration.
Ordering information Hardware 2680A Data Acquisition System Chassis, 6 slots 2686A Data Logging System Chassis, 6 slots, with ATA Flash memory drive, includes 1 GB ATA flash memory card 2680A-FAI Fast Analog Input Module 20 universal channels, 50 V max isolation.
NetDAQ Series ® Key NetDAQ® features • Expandable systems from 20 to 2000 analog channels • High accuracy readings, up to 0.01 % • High throughput, to support up to 1,000 ch/sec • Distributed design enables multiple users to view data remotely with standard browsers Fluke NetDAQ® NetDAQ® is designed to fit into your system The versatile NetDAQ system offers flexible options for data distribution. • Configure a dedicated system.
A system of up to 2000 channels can be configured by connecting multiple NetDAQ units to one PC NetDAQ® 2640A The Fluke NetDAQ 2640A delivers extremely high accuracy and resolution to provide calibrationlevel performance: • Measures up to 300 V at up to 100 rps • Offers 0.01 % V dc—0.
NetDAQ specifications • U niversal input module: Connect 20 analog inputs of virtually any sensor type without external signal conditioning • NetDAQ interfacing: Ethernet network cabling. RS-232 input for calibration • External trigger: Activate scanning with real-world events • Totalizer: Count on/off events, value reported with every scan • Alarm outputs: Flag out-of-limit conditions to external devices • Power: Accepts 107 to 264 V ac,or 9 to 16 V dc.
Ordering information 2640A NetDAQ Data Acquisition Unit (100 rps) 2645A NetDAQ Data Acquisition Unit (1,000 rps) Includes: Instrument, FlukeDAQ Software, Universal Input Module, manual on CD, power cable. Application software Digital inputs Threshold: 1.
Fluke DAQ Software The Fluke DAQ application is praised by users for its versatile handling of data acquisition and logging. Improved trending, file handling, web interface, web control, and convenient print functions for charts make this version of Fluke DAQ a feature-rich program. Fluke DAQ 6.0 is truly a program you can trust with your important data and analysis needs.
Version feature comparison Features 2680A-APSW (Full) 2680A-APSW/L (Lite) Multi-instrument configuration and operation Unlimited instruments (to 2000 channels) One instrument per configuration Configuration and CSV data file creation • • Trend chart and number of viewable trends 32 trends 4 trends Web connect thin client 4 instances OPC and DDE OPC, DDE Automated email alerts • Alarm page view • • History chart export • One license included with the following mainframe products 2640A
Trend Link for Fluke software Gain advanced trending capabilities Optional Trend Link for Fluke software is used in conjunction with FlukeDAQ application software.
Fluke measurement specification philosophy The accuracy specifications for the Fluke 2680 Series, 2638A Hydra Series III, and NetDAQ Series instruments are calculated conservatively so that they include three standard deviations from the nominal value— this is referred to as 3-Sigma. More than 99.7 % of the instruments produced will perform within the error limits.