User's Manual
Table Of Contents
- 233 Users Manual
- Introduction
- How to Contact Fluke
- Safety Information
- Hazardous Voltage
- Test Lead Alert
- Features
- Error Messages
- Battery Saver™(Sleep Mode)
- MIN MAX AVG Record Mode
- Display Hold
- Manual and Autoranging
- Backlight
- Power-Up Options
- How to Make Measurements
- Remote Operation
- Maintenance
- Service and Parts
- General Specifications
- Detailed Specifications
True-rms Remote Display Digital Multimeter
Detailed Specifications
41
AC Current
Function Range Resolution
Accuracy
(45 – 500 Hz)
6.000 A 0.001 A
A ac
[1,2,3]
10.00 A 0.01 A
±(1.5 % + 3)
[1] All ranges are specified from 5 % of range to 100 % of range.
[2] Crest factor of ≤3 at 4000 counts, decreasing linearly to 1.5 at full scale.
[3] AC current >10 A is unspecified. 20 A continuous overload for 30 seconds maximum.
DC Current
Function Range Resolution Accuracy
6.000 A 0.001 A
A dc
[1]
10.00 A 0.01 A
±(1.0 % + 3)