Force Drop - Writing anything to this item causes the BLE module to drop. This is a
work around for Apple related issues, per Brady H.
3.6. 0x2905 : Set Locator State
CC254x Module: Active as of 00.00.05
Set Locator State - write only uint8, 0 to turn off locator, 1 to turn on locator.
3.7. 0x2906 : IG Logging Status
CC254x Module: Active as of 00.00.06
IG Logging Status - read only uint8 array, 9 bytes.
o
Logging Status Data Description
Field
Logging State
Log - Total Bytes
Log - Used Bytes
Size in
bytes
1
4
4
Description
Logging state enum:
0:Idle, 1:Logging,
2:Not Supported
unsigned integer,
total number of bytes
for logging in bytes.
unsigned integer,
used bytes for
logging in bytes
3.8. 0x2907 : IG Logging Settings
CC254x Module: Active as of 00.00.06
IG Logging Settings - read / write uint8 array, 9 bytes.
o
Logging Settings Data Description
Field
Log - Interval
Log - Duration
Size in
bytes
4
4
Description
unsigned integer, logging
interval in seconds
unsigned integer, logging
duration in seconds
3.9. 0x2908 : IG Logging Control point
CC254x Module: Active as of 00.00.07
IG Logging Control point.