LinkRunner AT 1000/2000 ™ Network Auto-Tester Users Manual January 2012 © 2012 Fluke Corporation. All product names are trademarks of their respective companies.
LIMITED WARRANTY AND LIMITATION OF LIABILITY Each Fluke Networks product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period for the mainframe is one year and begins on the date of purchase. Parts, accessories, product repairs and services are warranted for 90 days, unless otherwise stated. Ni-Cad, Ni-MH and Li-Ion batteries, cables or other peripherals are all considered parts or accessories.
SOFTWARE NOTICE This product uses freeRTOS v6.0.5 software. For more information on freeRTOS, go to http://www.freertos.org. The software license statement and files that contain the binary and source code for freeRTOS v6.0.5 are on the LinkRunner AT CD supplied with this product. Copyright 2010 Real Time Engineering Ltd. Copyright 1998 Regents of the University of California. All rights reserved.
Contents Title Page Introduction .......................................................................................................................................................................... 1 Registering Your Product ..................................................................................................................................................... 1 The Fluke Networks Knowledge Base .............................................................................................
LinkRunner AT 1000/2000 Network Auto-Tester Users Manual AutoTest Configuration ................................................................................................................................................. 12 PoE Configuration .......................................................................................................................................................... 13 Connect Configuration .....................................................................................
List of Figures Figure 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. Page Physical Features ................................................................................................................................................... 4 The Home Screen ................................................................................................................................................. 6 How to Remove the Battery ..................................................................
LinkRunner AT 1000/2000 Network Auto-Tester Users Manual 18. 19. 20. 21. 22. 23. Cable Test Results ..................................................................................................................................................21 TruePowerTM Disabled PoE AutoTest Results .......................................................................................................22 TruePowerTM Disabled PoE Switch Results .........................................................................
LinkRunner AT 1000/2000 Network Auto-Tester Introduction Registering Your Product LinkRunner AT 1000/2000 Network Auto-Tester enables you to quickly verify Ethernet copper and fiber (2000 model only) cables, network connectivity and availability. In addition, the tester can be used for identifying the network device to which it is connected. It identifies PoE ports, provides a Report generating function, and can serve as a packet reflector for Fluke Networks performance tests.
LinkRunner AT 1000/2000 Network Auto-Tester Users Manual Contact Fluke Networks www.flukenetworks.com support@flukenetworks.com Safety Information Table 1 gives descriptions of the safety symbols used on the tester and in this manual. +1-425-446-4519 Table 1.
Unpacking WWarningX WCautions Use the proper terminals and cable for all connections. Use only the ac adapter provided to charge the battery. WWarnings To avoid possible electric shock or personal injury, follow these guidelines: Do not use this product if it is damaged. Before using the product, inspect the case. Look for cracked or missing plastic. Do not operate the product around explosive gas, vapor or dust. No serviceable parts. Do not try to service.
LinkRunner AT 1000/2000 Network Auto-Tester Users Manual Physical Features 7 6 8 9 5 16 17 10 11 15 4 12 13 3 19 2 14 18 1 ffy01.eps Figure 1.
Physical Features On/off key. Makes a selection on the screen. Shows the previous screen. Softkeys. The function of the softkey is shown above the key. Cable test wire mapping input. Connect the cable from the top Ethernet port to this port to view the wire map details. Ethernet 10/100/1000BASE-X port. Fiber port. Use one of the many supported SFP adapters to connect to the network. Tx/Rx - The LED blinks when the tester transmits and receives data.
LinkRunner AT 1000/2000 Network Auto-Tester Users Manual The Home Screen Switch: Shows the advertised and actual link, PoE A D B E C F measurements, nearest switch with its name, type, IP address, port, slot, and VLAN information. Cable: When the cable is connected un-terminated or is connected to a WireViewTM Office Locator, it shows cable information or wire mapping information. This can also be used to locate a cable with the optional IntelliToneTM probe. The name of the tester profile.
Battery Charging and Life Displays the connection type: PoE , 802.1x , fiber . For 802.1x, a green lock indicates authentication passed, yellow indicates it is not needed, and a red closed lock indicates it failed authentication. Battery Charging and Life To charge the battery, connect the ac adapter to the battery connector (see Figure 1). You can use the tester while you charge the battery. Figure 3 shows how to replace the battery.
LinkRunner AT 1000/2000 Network Auto-Tester Users Manual Common Questions LR-AT Can Solve First connect an RJ-45 or fiber cable (2000 model only) from the network hub or wall plate to the LinkRunner AT RJ-45 LAN or fiber port. Check the following list of questions and associated answers to see how LinkRunner AT can help you get the job done. Common Questions Q > Is this a good RJ45 Ethernet cable? A > Use Cable testing and the built in wiremap for patch cables, or an external WireviewTM Office Locator.
Common Questions LR-AT Can Solve Q> Can I connect in a MAC access control environment? A> Use Tools > VLAN/MAC to specify a user defined MAC address. Q > Do I have network connectivity? A > Select AutoTest to validate key network services (DHCP, DNS, Router). Q > Can I get an IPv4 DHCP address? A > Select AutoTest. Select DHCP (or enter a static IP address) in the Tools > IP Configuration menu. Q> Can I get an IPv6 address? A > Enable IPv6 in Tools > IP Configuration.
LinkRunner AT 1000/2000 Network Auto-Tester Users Manual Saving a Report Note You can save the current measurement data the tester has collected into a report that can be viewed and printed through the LinkRunner Manager PC application. This information includes: AutoTest results Switch results Cable test results To delete characters in the filename, press Backspace. To add characters to the filename, use to highlight a character, then press L.
Set Up the Tester Set Up the Tester IP Configuration To change settings on the tester, select Tools from the home screen. Select Tools > IP Configuration. ffy40.bmp Figure 5. IP Configuration Screen ffy23.bmp Figure 4. Tools Menu This screen allows you to enter an IPv4 address or use a DHCP address (default). It also allows you to enable IPv6 addressing (LR-AT 2000 only). LR-AT uses the IP address during AutoTest.
LinkRunner AT 1000/2000 Network Auto-Tester Users Manual VLAN/MAC Configuration AutoTest Configuration Select Tools > VLAN/MAC Configuration. Select Tools > AutoTest Configuration. ffy41.bmp ffy42.bmp Figure 6. VLAN/MAC Configuration Screen Figure 7. AutoTest Configuration Screen This screen allows you to enable and enter the VLAN IP and its Priority level. By un-checking the VLAN check box, the VLAN capability is disabled.
Set Up the Tester PoE Configuration Connect Configuration Select Tools > PoE Configuration. Select Tools > Connect Configuration. ffy43.bmp ffy34.bmp Figure 8. PoE Configuration Screen Figure 9. Connect Configuration Screen By default, PoE is disabled. This screen allows you to enable/ disable PoE detection, Enable TruePowerTM, and set the Class for detection. If you enable PoE and select Class 4 (25.5W), you can also enable LLDP Negotiation so that PoE is only reported if that criteria is met.
LinkRunner AT 1000/2000 Network Auto-Tester Users Manual General Configuration Reflector Configuration (LR-AT 2000 Model) Select Tools > General Configuration. This screen is used to configure the LR-AT 2000 for remote access to Fluke Networks EtherScope Network Assistant, MetroScope Service Provider, and OptiView Analyzer’s throughput performance tests. Note The LR-AT 2000 can reflect jumbo frame sizes up to 9600 bytes. Select Tools > Reflector.
Set Up the Tester Select Configure. Note Any other Reflector setting may cause undesired traffic on your network. LinkRunner Information Select Tools > LinkRunner Information. This screen displays the following LR-AT product information: Serial Number: The serial number is also shown under the battery pack. MAC Address: Media Access Control address. The unique address of the tester. The LR-AT 2000 must to be configured to: SW Version: The version of software in the tester.
LinkRunner AT 1000/2000 Network Auto-Tester Users Manual To Load a Profile 1 Select Tools > Manage files. 2 Select Load Profile. 3 Select a Profile from the list. To Save a Profile 1 Select Tools > Manage files. 2 Select Save Profile. The current setting are now saved to the profile filename shown at the bottom of the screen. To change the filename, select Edit. Manage Files 3 Select Save.
Set Up the Tester 3 Highlight either the Report or Profile folder. Restore Factory Defaults 4 Highlight the file, then press L. 5 To edit the filename, press Edit. Restores any configuration changes to the following LinkRunner AT factory defaults. To delete characters in the filename, press Delete. To add characters to the filename, use to highlight a character, then press L.
LinkRunner AT 1000/2000 Network Auto-Tester Users Manual General Configuration: Cable Length Unit, Meters Auto Shutoff, Enabled Set Language: English 6 Use the USB cable supplied with the tester to connect the tester to the PC. 7 In LinkRunner Manager, select LinkRunner > Update Software. When you Select Restore Factory Defaults, you will be prompted with a two popup. Select OK, then press L. 8 Click Select, find and select the update file (.zip extension), then click Select.
Using AutoTest, Switch, and Cable Test Transfer Saved Profiles to/from LinkRunner Manager Use LinkRunner Manager to view and configure the profiles that are saved on the tester. To transfer profiles from the tester to LinkRunner Manager: 1 Install the latest version of LinkRunner Manager software on your PC. Start the software. 2 Turn on the tester. 3 Use the USB cable supplied with the tester to connect the tester to the PC.
LinkRunner AT 1000/2000 Network Auto-Tester Users Manual The nearest switch is discovered and its name, port, VLAN ID, model, and IP address are displayed. Then the DHCP server information is displayed. Finally, the Gateway and DNS server(s) are displayed along with the target device(s). Expand on each device to display the test results as shown below. ffy28.bmp Figure 14. AutoTest Configuration Screen ffy31.bmp Select AutoTest on the Home screen.
Using AutoTest, Switch, and Cable Test Using the Nearest Switch Test Using the Cable Test The Switch test screen displays the nearest switch. The nearest switch is discovered by locating the “port advertisement” on the first few packets seen by LR-AT. There are three use models for using the Cable screen: Connect a cable from the top LR-AT RJ-45 connector into the side cable test RJ-45 connector to measure length and wire mapping.
LinkRunner AT 1000/2000 Network Auto-Tester Users Manual Using PoE Feature PoE is disabled by default. To enable PoE, select Tools > PoE Configuration, and check Enable PoE. Select the Class you want to verify. If you have purchased the LR-AT 2000, you can TruePowerTM test the Class. The results are displayed in the Autotest and Switch tests. When you select a PoE Class higher than the switch can handle, LR-AT 2000 will provide the loaded results indicating the switch can not handle this Class setting.
Using AutoTest, Switch, and Cable Test Using the Reflector Feature (LR-AT 2000 only) The Reflector feature allows the LR-AT 2000 to be used as a remote device for Fluke Networks EtherScope Network Assistant, MetroScope Service Provider, and the OptiView Analyzer’s throughput performance tests. ffy47.bmp See Reflector Configuration on page 14 for setting up this feature. Once set up, the device can be used as the remote responding device for throughput performance testing.
LinkRunner AT 1000/2000 Network Auto-Tester Users Manual ffy46.bmp Figure 23. Fiber Connected Switch Results Maintenance WWarningX To prevent possible fire, electrical shock, personal injury, or damage to the tester: Do not open the case. You cannot repair or replace parts in the case. Use only replacement parts that are approved by Fluke Networks.
Options and Accessories Options and Accessories Table 2 shows options and accessories available for the LinkRunner AT Tester. For a complete list of options and accessories visit the Fluke Networks website at www.flukenetworks.com. Table 2.
LinkRunner AT 1000/2000 Network Auto-Tester Users Manual Specifications Environmental Specifications Table 3. Environmental Specifications Operating temperature 32ºF to 113ºF (0ºC to +45ºC) Note The battery will not charge if the internal temperature of the tester is above 113ºF (45ºC).
Specifications General Specifications Table 4. General Specifications Media Access 10BASE-T, 100BASE-TX, 1000BASE-T (IEEE-802.3) and Poe (IEEE 802.3at) Cable Test Pair lengths, opens, shorts, splits, crossed, straight through, and cable ID Tone Generator IntelliTone digital tone: [500 KHz]; analog tones: [400Hz, 1KHz] Ports Dimensions RJ45 copper port 1000BASE-X fiber adapter port (2000 only) 3.5 in x 7.8 in x 1.9 in (8.9 cm x 19.8 cm x 4.8 cm) Weight 18 oz (0.
LinkRunner AT 1000/2000 Network Auto-Tester Users Manual LinkRunner Manager Software Table 5.