Validating Ethernet Service
11
Validating Ethernet Service
The toner detects link pulses for 10BASE-T, 100BASE-TX,
and 1000BASE-T Ethernet service on pins 1, 2 and 3, 6 of its
RJ45 jack.
1
Turn off the toner.
2
Connect the toner to the circuit as shown in Figure 3.
3
Turn the toner’s rotary switch to SERVICE.
4
The Ethernet LED indicates service on pins 1, 2 or 3, 6
as shown in Figure 3.
The toner checks for continuity between pins 4, 5.
Continuity indicates the toner is connected to a network
device that is turned off.
The toner checks for continuity between the red and black
test leads and across the middle pair of the RJ45/RJ11 jack
(line 1).
Note
If the Ethernet LED alternates between red and
green, th
e
Ethernet service is Auto-MDIX.
ASH01.EPS
Figure 3. Validating Ethernet Service
Punch-down
block
RJ45
RJ11
SERVICE
Red:
service on 1, 2
Continuity or
non-Ethernet
voltage
No voltage
No continuity
Green:
service on 3, 6