Locating and Isolating Terminated UTP/STP Cables with the IntelliTone
5
In locating mode, the probe’s LEDs light up from 1 to 8
as the signal strength increases. The higher the
number, the stronger the signal.
Note
If you cannot locate the IntelliTone signal on 2-
conductor cabl
es, the cable may be shorted. Use
the cable map test (page 8) to test for shorts on
cables with RJ11 and RJ45 connectors. Use the
continui
ty test (page 12) to check for shorts on
coax and non-terminated cables.
5
Turn the probe’s rotary switch to (isolate).
6
Use the probe to isolate the tone source in the cable
bundle or at the patch panel. The SYNC LED lights up
green when the probe is receiving the IntelliTone
signal.
In isolating mode, the probes LEDs light up from 1 to 8 as
the signal strength increases.