Operation Manual
Versiv Cabling Certification Product Family
Users Manual
86
To do the FiberInspector test
Refer to Figures 34 and 35.
1 Connect the FI-1000 probe to the type A USB port on the side
of the tester.
2 Install the correct tip on the probe.
3 Clean the connector that you will inspect.
4 Do the FiberInspector test:
To do the FiberInspector test when it is in the project
If the FiberInspector test does not already show on the home
screen:
a. On the home screen, tap the test setup panel.
b. On the CHANGE TEST screen, tap the FiberInspector test,
then tap USE SELECTED.
c. Tap Test or press .
To do the FiberInspector test when it is not in a project
On the home screen, tap the TOOLS icon, then tap
FiberInspector.
5 Insert the probe into the connector.
6 To adjust the focus, turn the dial on the probe clockwise or
counterclockwise.
Figure 36 shows an example of a FiberInspector image.
7 To save the image, tap SAVE.
8 On the SAVE RESULT screen, select End 1 or End 2, make sure
the Cable ID and End name are correct, then tap SAVE.
Saved FiberInspector results show these icons for End 1 and End
2: