Operation Manual

Chapter 11: Use Projects
About Next ID Sets
219
Note
The tester does not increment symbols or
accented characters.
When you use an ID set that does not have a Last ID, the set
under IDs Untested on the CHANGE ID screen shows only the
next ID.
Total IDs: The number of IDs in the set. This section does not
show for ID sets that do not have a Last ID.
Select Media: Select Copper to use the ID set for test results
from copper cable.
Select Fiber and one or more fiber tests to use the ID set for test
results from fiber cable.
For example, you can specify that you must do a Loss Length
and a FiberInspector test for each ID. After you do both tests for
all the IDs in the set, the tester shows 100% Tested on the home
screen. If no IDs include FiberInspector results, the tester shows
50%. To see the IDs that need FiberInspector results, select a
FiberInspector test in the project, then look at the list under
FiberInspector IDs Untested on the CHANGE ID screen
Notes
You can use an ID set only for results from the
media type you selected under Select Media.
The Select Media section does not show for ID sets
that do not have a Last ID. You can use these ID
sets for copper or fiber results.
Tap IMPORT to use an ID set that you downloaded to the tester
from LinkWare PC software.
Tap REVIEW to see the CABLE ID REVIEW screen, which shows
the ID set an the total number of IDs.
Note
The REVIEW button does not show if you do not
enter a Last ID.
SAVE: To save the ID set, tap SAVE.