Operation Manual
Versiv Cabling Certification Product Family
Users Manual
48
Return loss
TCL (transverse conversion loss)
CDNEXT (common-mode to differential mode near-end
crosstalk)
CMRL (common-mode return loss)
ELTCTL (equal level transverse conversion transfer loss)
HDTDR and HDTDX analyzers (optional tests, not required by
any test limit)
Automatic Diagnostics
If an Autotest on twisted pair cabling fails, the DSX-5000
CableAnalyzer automatically gives you information about faults.
To see the information, tap the FAULT INFO tab. Figure 18 shows
examples of diagnostic information.
To get only diagnostics results, select Diagnostics from the TOOLS
menu. These results do not include a PASS/FAIL status.
The diagnostic screens show connectors in grey when other faults
possibly affect the results for the connector.
For NEXT failures caused by multiple connectors, the diagnostic
screen shows the worst connector in red.
Future Versiv software releases may include additional
diagnostics. The latest software is available at no charge on the
Fluke Networks website.
For more information on diagnostics, including video training
modules, see the Knowledge Base on the Fluke Networks website.