DIAGNOSTIC and FAULT INFO Tabs
If the Autotest failed or had a marginal result, the FAULT INFO
tab shows. If the test passed and you selected All Autotests for
the HDTDR/HDTDX setting on the TEST SETUP screen, the
DIAGNOSTIC tab shows. These tabs give you access to the HDTDR
and HDTDX analyzer plots. The plots help you locate the causes of
NEXT and return loss failures. See the Technical Reference
Handbook.
Continuous Tests
To do the wire map, length, or resistance test continuously, go to
the home screen, tap TOOLS > Single Tests, then tap a test.
The wire map test compares the results to the outlet
configuration specified by the selected test limit and shows if
the connections agree or if they do not.
The length and resistance tests do not compare the results to a
test limit.
To save the result, tap SCAN OFF > SAVE. The saved test has an
for the overall result.
About the AxTalk Analyzer Kit
The DSX-5000 kit includes the hardware and AxTalk Analyzer
software you need to do tests for alien crosstalk on twisted pair
cabling. Alien crosstalk is noise, or crosstalk, transmitted between
adjacent cables in a bundle or patch panel. Alien crosstalk is a
primary source of noise in cabling used for 10GBASE-T
applications.
For instructions on how to do alien crosstalk tests, install the
AxTalk Analyzer software, which is available on the Fluke
Networks website, then see the online help in the software.