User Manual

1662/1663/1664 FC
Manuale d'Uso
88
Incertezze e gamme operative a norma EN 61557
Funzione Gamma display
Incertezza
operativa della
gamma di misura
EN 61557
Valori Nominali
V
EN 61557-1
0,0 V c.a. – 500 V c.a.
50 V c.a. – 500 V c.a.
±(2% + 2 cfr)
U
N
= 230/400 V c.a.
f = 50/60 Hz
RLO
EN 61557-4
0,00 Ω – 2000 Ω
0,2 Ω – 2000 Ω
±(10 % + 2 cfr)
4,0 V c.c. < U
Q
< 24 V c.c.
R
LO
2,00 Ω I
N
200 mA
RISO
EN 61557-2
0,00 MΩ – 1000 MΩ
1 MΩ – 200 MΩ
±(10 % + 2 cfr)
200 MΩ – 1000 MΩ
±(15 % + 2 cfr)
U
N
= 50/100/250/500/1000 V
c.c.
I
N
= 1,0 mA
ZI
EN 61557-3
Z
I
(Nessun intervento)
0,00 Ω – 2000 Ω
0,4 Ω – 2000 Ω
±(15
% + 6 cfr)
U
N
= 230/400 V c.a.
f = 50/60 Hz
I
K
= 0 A – 10,0 kA
Z
I
(Alta corrente)
0,00 Ω – 2000 Ω
0,2 Ω – 200 Ω
±(10 % + 4 cfr)
Z
I
(Alta corrente, resist.
elevata)
0 mΩ – 9999 mΩ
100 mΩ – 9999 mΩ
±(8 % + 20 cfr)
R
E
0,00 Ω – 2000 Ω
10 Ω – 1000 Ω
±(10 % + 2 cfr)
Δ
T, I
Δ
N
EN 61557-6
Δ
T
0,0 ms – 2000 ms
25 ms – 2000 ms
±(10 % + 1 cfr)
Δ
T a 10 / 30 / 100 / 300 / 500 /
1000 / VAR mA
I
ΔN
3 mA – 550 mA
(VAR 3 mA – 700 mA)
3 mA – 550 mA
±
(10 % + 1 cfr)
I
ΔN
=
10/30/100/300/500/VAR mA
RE
EN 61557-5
0,0 Ω – 2000 Ω
10 Ω – 2000 Ω
±(10 % + 2 cfr)
f = 128 Hz
Fase
EN 61557-7
1: 2: 3
Nota: cfr = cifre