Data Sheet
5 Fluke Corporation Fluke 1750 Three-Phase Power Recorder
Optional accessories
Fluke power quality current
transformers and flexible
current probes are specially
designed to work seamlessly
with Fluke power monitors
(1750 and 1650). All clamp-
on and flexi-CT’s are matched
to take full advantage of your
instrument’s ability to set scale
factors for accurate readings.
Cases
1750/CASE Transit Case
• Rugged water tight transit case
with rollers
CS1750/1760
• Soft carrying case for Fluke
1750 and 1760
Miscellaneous
1750/MC
• Additional SD Memory Card
for Fluke 1750
Fluke-1750 TABLET
• Android Remote Controller
1750/SEAT-L
• Fluke Power Analyze–
Additional seat license
• One additional license
for installation on one
additional PC
1750/SITE-L
• Fluke Power Analyze-
Additional seat license
• Site license for installation on
unlimited PCs
ST1760
• Standard ethernet cable
Model no. CT type Current range Accuracy
Frequency
response Jaw opening
i5S-PR Clamp-On 0.01 A to 5 A 1 % RDG ± 0.5 % FS 5 kHz 1.5 cm (0.6 in) dia.
i40S-PR Clamp-On 0.1 A to 40 A 1 % RDG ± 0.1 % FS 5 kHz 1.5 cm (0.6 in) dia.
3140R Clamp-On 2 A to 400 A 2 % RDG ± 0.04 A 20 kHz 3.2 cm (1.25 in) dia.
Model no. CT type Current range Accuracy
Frequency
response Probe length
3210-PR TF-II Flexi-CT 20 A to 1000 A 1 % rdg ± 0.15 % FS 7 kHz 60 cm (24 in)
3310-PR -TF-II Flexi-CT 100 A to 5000 A 1 % rdg ± 0.15 % FS 7 kHz 60 cm (24 in)
3312-PR TF-II Flexi-CT 100 A to 5000 A 1 % rdg ± 0.15 % FS 7 kHz 120 cm (48 in)