Brochure

Connect-and-View
triggering for an instant,
stable display
If you’ve used other scopes, you
know how tricky triggering can
be. If settings are
incorrect, results
can be unstable or
incorrect. Connect-and-View
automatically sets up correct
triggering by recognizing signal
patterns. Without touching a
button, you get a stable, reli-
able and repeatable display of
virtually any signal including
motor drive and control signals.
It’s especially fast and conve-
nient when you’re measuring a
number of test points in rapid
succession.
Built-in digital multimeter
Conveniently switch from
waveform analysis to precise
multimeter measurements using
the built in 5000 count digi-
tal multimeter. Measurement
functions include Vdc, Vac,
Vac+dc, resistance, continuity
and diode test. Measure current
and temperature using suitable
shunt, probe or adapter with
wide range of scaling factors.
ScopeRecord mode for
high resolution waveform
recording up to 48 hours
ScopeRecord memory stores up
to 30,000 or more data points
per channel, capturing fast inter-
mittents and glitches as short
as 8 ns. (Two sets of multiple-
channel recordings can be
stored for later analysis.)
Records events like motion
profiles and UPS, power supply
or motor start-up cycles
With the Stop on Trigger
mode, the ScopeMeter
®
test
tool automatically recognizes
a power failure and stores the
waveform data preceding it
TrendPlot paperless
recorder—records up to
22 days to help you find
intermittent faults
The toughest faults to find are
those that happen once in a
while. These intermittents can
be caused by bad connections,
dust, dirt, corrosion, or simply
broken wiring or connectors.
Line outages, sags or starting
and stopping of a motor can
also cause a machine to stop.
You may not be around when
it happens, but the Fluke
ScopeMeter
®
test tool will be.
Plot minimum and maximum
peak values and average over
time up to 22 days
Plot any combination of volt-
ages, amps, temperature,
frequency and phase for all
inputs, all with time and date
stamp to pinpoint faults
Capture high-resolution waveform
details over extended period using
ScopeRecord
mode.
Fluke ScopeMeter
®
test tools work
harder to make
your job easier
See what’s happening with fast
real-time high resolution sampling.
ScopeMeter
®
portable oscilloscopes
offer a sample rate of up to 5 GS/s
with up to 200 ps resolution.
The built in multimeter provides conve-
nient precision measurements.
Trend multiple measurements captur-
ing signal intermittent events, signal
drift or fluctuations.
Connect-and-View
captures even the
most complex motor drive signals.
6