User's Manual

ScopeMeter® Test Tool 190 Series II
Users Manual
72
Saving and Recalling
You can:
Save screens and setups to internal memory, and
recall them again from memory. The test tool has 30
screen and setupmemories, 10 ‘record and setup
memories, and 9 screen image memories. See also
Table 1.
Save up to 256 screens and setups to a USB memory
device, and recall them again from memory.
Name saved screens and setups according to your
own preferences.
Recall screens and recordings to analyze the screen
image at a later date.
Recall a setup to continue a measurement with the
recalled operating configuration.
Notes
Saved data is stored in non-volatile Flash
memory.
Not saved instrument data is stored in RAM
memory and will be kept at least 30 seconds
when the battery is removed when no power is
supplied via the BC190 power adapter.
Table 1. Test Tool Internal Memory
Mode
Memory locations
30x
10x
9x
METER Setup +
1 screen
- Screen image
SCOPE Setup +
1 screen
Setup +
100 replay
screens
Screen image
SCOPE REC - Setup +
record data
Screen image
TRENDPLOT - Setup +
trendplot data
Screen image
Notes:
- In persistence mode, the most recent
waveform will be saved, not all
waveforms that build the persistence
display.