LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for three years from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf.
Introduction The Fluke 233 (hereafter the Meter) is a compact and easy to operate tool for electrical and electronic circuit measurements. XWWarning Read "Safety Information" before you use the Meter.
233 Getting Started Manual Safety Information The Meter complies with: • • • • • • • • • ISA-82.02.01 CAN/CSA C22.2 No. 61010-1-04 ANSI/UL 61010-1:2004 EN 61010-1:2001 EN 61326-1:2006 EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006 ETSI EN 300 489 V1.8.1:2008 FCC Part 15 Subpart C Sections 15.207, 15.209, 15.
True-rms Remote Display Digital Multimeter Safety Information • Remove the test leads from the Meter before the battery door on the Meter base is opened. • Examine the test leads for damaged insulation or exposed metal. Measure the test leads for continuity. Replace damaged test leads before you use the Meter. • Do not apply more than the rated voltage, shown on the Meter, between the terminals or between a terminal and earth ground.
233 Getting Started Manual • 4 Use only specified 1.5-V AA batteries (three in the Meter base and two in the display), correctly installed, for Meter power. • Comply with local and national safety requirements when in hazardous locations. • Only use test leads that have the same voltage, category, and amperage ratings as the Meter and that are approved by a safety Agency. • Measure a known voltage first to make sure that the Meter operates correctly. If you are unsure, have the Meter examined.
True-rms Remote Display Digital Multimeter Safety Information Table 1. Electrical Symbols B AC (Alternating Current) F DC (Direct Current) I Fuse X Hazardous voltage P Conforms to European Union directives. W Risk of Danger. Important information. See Manual. ) Conforms to relevant Canadian Standards Association directives. Battery. Low battery when shown. T Double insulated R Continuity test or continuity beeper tone.
233 Getting Started Manual Features See Tables 3 through 4 for a list of Meter features with a short feature description. Table 2. Display 2 1 4 3 5 14 13 6 12 meter 11 Auto RangeManual Range remote 10 7 9 8 gcc101.eps 6 No. Symbol 1 2 MAX MIN AVG 3 Indication MIN MAX AVG mode on. Maximum, minimum, or average measurement shown. Display hold on. Display freezes the measurement.
True-rms Remote Display Digital Multimeter Features Table 2. Display (cont.) No. Symbol 4 5 °C, °F 6 A Indication Radio connection indicator. degrees Celsius, degrees Fahrenheit amperes (amps) V, mV volts, millivolts μF, nF microfarad, nanofarad DC AC Direct current or alternating current. Ω, MΩ, kΩ Hz, kHz ohm, megohm, kilohm hertz, kilohertz 7 remote Battery low warning for the display module. 8 Manual Range 9 Auto Range Auto range set.
233 Getting Started Manual Table 3. Inputs 1 3 2 gcc110.eps 8 No. Terminal Description 1 A 2 COM Common terminal for all measurements. 3 Input for voltage, continuity, resistance, diode, capacitance, temperature, and frequency measurements. Input for 0 A to 10.00 A current measurements.
True-rms Remote Display Digital Multimeter Features Table 4. Function Switch Positions Switch Position Hz (button) e Hz (button) Description AC voltage from 0.06 to 1000 V. Frequency from 5 Hz to 50 kHz. DC voltage from 0.001 V to 1000 V. AC voltage from 6.0 to 600.0 mV, dc-coupled. DC voltage from 0.1 to 600.0 mV. Ohms from 0.1 Ω to 40 MΩ. Continuity beeper turns on at <20 Ω and turns off at >250 Ω. Farads from 1 nF to 9999 μF. Diode Test.
233 Getting Started Manual Error Messages Table 5 contains possible error messages and the steps to clear the error. Table 5. Error Messages Error Messages Display-module batteries must be replaced before the Meter will operate. Meter-base batteries must be replaced before the Meter will operate. Calibration necessary. Meter calibration is necessary before the Meter will operate. Internal error. The Meter must be repaired before it will operate.
True-rms Remote Display Digital Multimeter Remote Operation Remote Operation 1 1 2 2 gcc114.eps Figure 1. Display Module Separation gcc115.eps Figure 2.
233 Getting Started Manual Fuse Test Battery Replacement 2 Good fuse: 0.0 Ω to 0.5 Ω Replace fuse: OL 3 gcc111.eps gcc105.eps Figure 3. Fuse Test 12 Figure 4.
True-rms Remote Display Digital Multimeter Battery Replacement 1 2 4 3 gcc112.eps Figure 5.
233 Getting Started Manual General Specifications Maximum voltage between any terminal and earth ground ........................................... 1000 V rms W Fuse for A inputs ..................................................... 11 A, 1000 V 17000A interrupt rating Fuse Altitude Operating .................................................................... 2,000 meters Storage ....................................................................... 12,000 meters Temperature Operating ...................