User's Manual
Wireless AC Clamp
Specifications
5
Specifications
Range ..................................................................... 400.0 A
Resolution ............................................................... 0.1 A
Accuracy
400.0 A ............................................................... 2 % ±5 digits (45 Hz to 65 Hz), 2.5 % ±5 digits (65 Hz to 400 Hz)
Inrush .................................................................. Maximum displayed reading is 999.9 A
Crest Factor (50 Hz/60 Hz) ..................................... 3 at 180 A, 2.5 at 220 A, 1.42 at 400 A, add 2 % for C.F. >2
LCD w/Backlight ...................................................... 3 ½ digits
Log Rate/Interval ..................................................... 1 second to 1 hour adjustable by PC, default, 1 minute
Battery Type ............................................................ 2 AA, NEDA 15 A, IEC LR6
Battery Life .............................................................. 250 hours
Memory ................................................................... Record a maximum of 65,000 readings
Radio Frequency Communications ......................... 2.4 GHz ISM Band
Radio Frequency Communication Range ............... 20 m (66 ft)
Radio Frequency Certification................................. FCC: T68-FBLE; IC: 6627A-FBLE
Operating Temperature ........................................... -10 °C to +50 °C (14 °F to 122 °F)
Storage Temperature .............................................. -40 °C to +60 °C (-40 °F to 140 °F)
Operating Humidity ................................................. 90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
(90 % at 95 °F, 75 % at 104 °F, 45 % at 122 °F)
Operating Altitude ................................................... 2,000 m
Storage Altitude ...................................................... 12,000 m
Ingress Protection (IP) rating .................................. IP30
Safety ...................................................................... IEC 61010-1I, Pollution Degree 2
IEC 61010-2-033:Measurement 1000V CAT III/600V CATIV
Electromagnetic Compatibility................................. Radio Frequency Emissions, IEC CISPR 11: Group 1, Class A.
Group 1 have intentionally generated and/or use conductively coupled
radio-frequency energy which is necessary for the internal functioning
of the equipment itself.
Class A equipment is suitable for use in non-domestic locations and/or
directly connected to a low-voltage power supply network. Class A
equipment may have potential difficulties in ensuring electromagnetic
compatibility in other environments due to conducted as well as
radiated disturbances.
Applies to use in Korea only ............................... Class A Equipment (Industrial Broadcasting & Communication
Equipment)
[1]
[1] This product meets requirements for industrial (Class A) electromagnetic
wave equipment and the seller or user should take notice of it. This
equipment is intended for use in business environments and is not to be
used in homes.
Electromagnetic Environment ........................... IEC 61326-1: Portable
Temperature Coefficient ......................................... Add 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C)
Add 0.1 X (specified accuracy)/ °F (<64.4 °F or >82.4 °F)
Size ......................................................................... 185.5 mm x 75.0 mm x 35.5 mm (7.3 in x 2.9 in x 1.4 in)
Weight ..................................................................... 0.283 kg (10 oz)
Jaw Opening ........................................................... 30.0 mm (1.2 in)