Brochure

Clamp Meter selection chart cont.
Job functions Applications Recommended clamp
Comm/Ind Electrical
Electrical Contractor
Working on panels and branch circuits
Measure loads on a branch circuit at a
panel (including feeder cables, branch
circuits and neutrals) and the continuity of
switches, fuses and contacts
Measure load side voltage of a breaker or
fuse
Check if a circuit is live before beginning
work
T5-1000 Electrical Tester
Key features
Open jaw ac current measurement to 100 A
AC and dc voltage
T5-600: CAT III 600 V
T5-1000: CAT IV 600 V, CAT III 1000 V
Continuity, resistance
Rugged and easy to use
Facility Maintenance
Commercial Electrician
Leakage
Facility Maintenance
Electrician
Measuring leakage current
Check insulation condition and leakage of
circuits and systems
Check for leakage in circuits and systems
utilizing filters
Testing insulation on live circuits
Evaluate insulation condition on live
circuits via leakage current measurements
where disconnection is highly inconvenient
360 AC Leakage Current Clamp Meter
Key features
Measurement of leakage current with 3 mA range and
1 µA of resolution for accurate monitoring of insulation
erosion
Broad range of measurement from 1 µA up to 60 A, for
all installation needs
Advanced shielding to ensure accurate results when
measuring near other conductors
Easy-to-carry, pocket-sized leakage current tester with
wide 40 mm (1.5 in) jaw size
CAT III 300 V
Hospital Electrician
Electrical Contractor
Earth Ground
Industrial/Commercial
Maintenance Electrician
Grounding and bonding resistance testing
Perform ground loop tests in areas where
other ground resistance test techniques are
not available
Test parts of a multi-grounded system
Periodically perform quick tests on system
grounds as part of a regular preventative
maintenance program
1630 Earth Ground Clamp Meter
Key features
Measure from 0.025 Ω to 1500 Ω ground loop
resistance
Large jaw for clamping around the widest range of
ground conductors or grounding bars
Measure ground leakage and ac load currents from
0.2 mA all the way up to 30 A
User defined alarm limits for rapid pass/fail type
measurements
CAT III 300 V
Utility Technician
Electrical Contractor/
Consultant
Process
Process Technician/
Electrician
Measuring process control signals
Measures 4-20 mA signals without break-
ing the loop
Check correct operation of PLCs and control
systems analog I/O
Source process control signals allow for
testing of 4-20 mA signals and 1 to 5 V
and 0 to 10 V to test automation I/O
Advanced troubleshooting features simplify
loop testing
773 Milliamp Process Clamp Meter
Key features
Saves time and money by easily measuring 4-20 mA
signals
Detatchable miniature clamp for tight locations
Also measure older 10 to 50 mA signal systems with
the 100 mA range
Backlit display, spotlight, display hold and zero-reading
buttons
Eliminates the need for extra 4-20 mA source or
voltage equipment when troubleshooting
CAT II 300 V
Automation Specialist/