Brochure

Job functions Applications Recommended clamp
Power Quality
Electrical and Field
Service Technician
Measuring non-linear loads
Setup and troubleshoot variable frequency
drives and UPS systems—Verify correct
operation by measuring key power quality
parameters
Harmonic measurements
Uncover harmonic issues that can damage
or disrupt critical equipment
Troubleshooting start-up current issues
Check start-up current where spurious
resets or nuisance circuit breaker tripping
occurs
Load studies
Verify electrical system capacity before
adding loads
345 Power Quality Clamp Meter
Key features
AC/DC current: Clamp-on measurement of current up to
1400 A ac rms and 2000 A dc
CAT IV 600 V rated for use at the service entrance
Accurate in noisy environments: Using low-pass
filter, the clamp meter performs even with distorted
waveforms
Data logging: Identify intermittent faults by logging any
power quality parameter for minutes, or over a month
Troubleshoot harmonics: Analyze and log harmonics
digitally or graphically
Inrush current: Capture and analyze nuisance tripping,
from 3 seconds to 300 seconds
CAT IV 600 V, CAT III 1000 V
HVAC/R Technician
Electrical Engineer
Commercial Electrician
Facility Maintenance
Electrician
Electric Utility Engineer
High-End Industrial Utility
Industrial Service
Electrician
Service panel, service entrance and low
voltage vaults
In the service panel, clamp around each
individual phase. Good for large single or
parallel conductors
In the service entrance, clamp around
busbars, up to 2.5 in, to verify expected
current usage
Measure current in conductors of low-
voltage vaults (1000 V or less)
Working with large loads
Verify operation of large load service
panels, switchgears, large current DC
systems and motors
355 True-rms 2000 A Clamp Meter
Key features
Up to 2000 A dc, 1400 A ac current measurement
Large jaw suitable for single or multiple large
conductors
CAT IV 600 V rated for maximum application versatility
Inputs for 600 V ac, 1000 V dc, 400 KΩ resistance and
continuity
Low pass filter, min/max/avg and inrush current
Accurately measure frequency of current and voltage up
to 1 kHz
CAT IV 600 V, CAT III 1000 V
Electrical Contractor
Electric Utility Technician
Marine or Welding
Electrician
Facility Maintenance
Electrician
HVAC/R
HVAC/R Service
Technician
Checking boilers and furnaces
Capture flue gas temperatures and perform
flame rod testing
HVAC motors and drives
Measure start and run motor capacitors
Troubleshoot compressor electrical motor
faults
Measure performance of variable frequency
drives
Testing electrical performance
Measure load-side and supply-side current
and voltage
Measure current and voltage phase balance
on 3 phase systems
902 True-rms HVAC Clamp Meter
Key features
Measure current up to 600 A ac and up to 200 µA dc
Measure true-rms voltage, capacitance, resistance and
continuity
Measure contact temperature with included Type-K
temperature probe. (Or measure the outside temperature
of a pipe with the 80PK-8 Pipe Clamp Temperature
Probe, sold separately)
CAT III 600 V
Genuine Fluke Accessories
When your job depends on every tool in your toolbox, Genuine
Fluke Accessories keep you working.
Visit www.uke.com/accessor y to search our accessory
inventory by product model, accessory model or category.