Gasket Compression Table
Tighten taptite screws until gasket compresses as listed
in Table 4.
Note
Take all measurements with digital vernier calipers.
Table 4.
2″ Compression Table
Standard Gasket Premier Gasket
U/C C U/C C
16.8 mm 16.3 mm 16.3 mm 15.0 mm
0.663″ 0.643″ 0.643″ 0.591″
3″ Compression Table
16.8 mm 16.3 mm 16.3 mm 15.0 mm
0.663″ 0.643″ 0.643″ 0.591″
4″ Compression Table
20.4 mm 19.9 mm N/A N/A
0.805″ 0.784″ N/A N/A
U/C = Overall dimension - Exterior of security
cover to front face of the panel with gasket
uncompressed.
C = Overall dimension - Exterior of security cover to
front face of the panel with gasket compressed.
Step 9: De-Burr the Holes, Remove any Shavings and
the Self Adhesive Template
Degrease the front panel.
Step 10: Fix Infrared Window
Peel off the protective cover from the rear panel gasket on
the Infrared Window’s mounting frame (Figure 12).
Align the xing holes and rmly press the Infrared Window
into place (Figure 13).
Using the correct sized screwdriver and the countersunk
screws provided, x back the Infrared Window
(Figure 14).
Gradually advance each xing until the gasket is seen to
compress evenly. Refer to Table 4.
Step 11 - Fitting Security Cover
Peel off the cover from the 2-hole gasket (Figure 15).
Align the gasket with the two xing holes positioned
vertically and press the gasket into position (Figure 16).
Fit the security cover using the two security screws
provided (Figure 17).
The Infrared Window is ready to use. Remember to
remove the cover before imaging (Figure 18).
1.888.475.5235info@Fluke-Direct.com
Fluk e-Direct
.com