Data Sheet

Technical Data
The Best Just Got Better.
The new 289 is the next generation high performance industrial logging mul-
timeter designed to solve complex problems in electronics, plant automation,
power distribution, and electro-mechanical equipment. With the ability to
log data and review it graphically on-screen, you can solve problems
faster and help minimize downtime. Let the new 289 be your
watchdog for systems or processes while you are off solving
other problems.
New Two terminal 50 ohm
range with 1 milliohm resolu-
tion, 10 mA source current.
Useful for measuring and
comparing differences in motor
winding resistance or contact
resistance.
New Low Pass filter for
accurate voltage and frequency
measurements at the same
time on adjustable speed
motor drives and other electri-
cally noisy equipment
New LoZ Volts. Low imped-
ance voltage function for
eliminating ghost voltages.
Also recommended when test-
ing for absence or presence of
live power.
New button. On board
help screens for measure-
ment functions. Unsure about
a function—go to that function
and press the “i” button.
Real time clock for automatic
time stamping of saved
readings
New Fluke 289
True-rms Industrial Logging
Multimeter with TrendCapture
R
N10140
Equipped with new
functionality
New TrendCapture quickly
graphically displays logged
data session to quickly deter-
mine whether anomalies may
have occurred
New Zoom on trend provides
unprecedented ability to view
and analyze TrendCapture
data; zoom in up to 14 times
New Selectable ac filter
(Smoothing mode) helps dis-
play a steadier reading when
the input signal is changing
rapidly or noisy
New Adjustable record-
ing and auto hold thresholds,
specify a percentage change
in the readings that begins a
new event
New Large 50,000 count,
1/4 VGA dot matrix display
with white backlight
New Logging function with
expanded memory for unat-
tended monitoring of signals
over time. Using on-board
TrendCapture users can graph-
ically review logged readings
without needing a PC. Store
up to 15,000 recorded events.
New Save multiple logging
sessions before pc download
is necessary
Relative mode to remove test
lead resistance from low ohms
or capacitance measurements
True-rms ac voltage and
current for accurate measure-
ments on non linear signals
Measure up to 10 A (20 A for
30 seconds)
100 mF capacitance range
Peak capture to record tran-
sients as fast as 250 µs
Optional magnetic hanger
for easy setup and viewing
while freeing your hands for
other tasks
Optically isolated communica-
tion port for transferring data
to pc (usb cable and software
optional)
Limited lifetime warranty
TrendCapture displays vDC logged date.

Summary of content (2 pages)