User manual

Features
Model
T90 T110VDE T130VDE T150VDE
Complies with EN 61243-3:2010
LED Indication Range: 12 V to 690 V dc and ac
V Display: Multiple LED Bargraph
Independent ELV indicator LED, indicates if >50 V ac/120 V dc is
present even in the event of no battery power or main circuit failure
LCD Indication Range: 6 V to 690 V dc and ac
V Display: Digital LCD 3½ digit (1 V resolution)
Resistance Measurement: LCD 3½ digit (0 to 1999 Ω/1Ω resolution)
LCD Backlight
Display HOLD: Freeze/unfreeze display with voltage or resistance
measurement
CAT II 690 V / CAT III 600 V
CAT III 690 V / CAT IV 600 V
Rugged, Double-Insulated Wire
Fixed Impedance ~200 kΩ (3.5 mA @ 690 V)
Switchable Load by 2 pushbuttons (~30 mA @ 230 V)
Vibration During Load (when 2 switchable load pushbuttons are
pushed)
Single-Pole Phase Test (also operates with gloves)
Rotary Field Direction (also operates with gloves)
Continuity Test / Diode Test
Torch
Beeper for Continuity/Phase/ACV
IP54
IP64
Slim Metal Probe Tips (threaded base for included tip accessories)
Probe Tip Protector Cap (secure storage for the docked probes)
4 mm Probe Tip Thickness Extensions (for better t in outlets)
19 mm Probe Tip distance when docked
Probe Tip Sheath (UK GS38 sheath–keeps the exposed metal to a
<4 mm limit)
Slim Probe for Ultra-Compact Form Factor
Display
LEDs
(All Models)
Description
y
x
w
v
u
t
s
Voltage level is backlit
z
Voltage level is more than ELV
limit (>50 V ac or >120 V dc)
a
Voltage is ac / phase in Single
Pole Phase test
d
DC
e
Voltage is positive or negative at
the indicator probe
b
Battery is low / Replace battery
f
Continuity or diode in forward
operation
g
Switchable load is ON (two buttons
pressed and current ows)
q r
3-phase sequence indication
detected left or right turning
phases with nonindicator probe
(L1) to indicator probe (L2)
1
3
2
4
5
6
gpn76.eps
LCD
(T130VDE/
T150VDE)
Description
Display is in HOLD mode
Voltage measurement (T130VDE/
T150VDE) or resistance
measurement (T150VDE)
Resistance measurement
(T150VDE)
AC Voltage measurement
DC Voltage measurement
Battery is low / Replace battery
How to Hold the Tester
Always hold the product behind the barrier to keep the
display in view. See Figure 4.
 Warning
To prevent possible electric shock, never
touch the metal pins of the probes when
power is applied.
Self‑Test
The Tester has a built-in self test function.
Before and after use, do a self-test:
1. Touch and hold the probe tips together.
f shows and you can hear the beeper. This
makes sure that the test leads have continuity.
2. Make sure that:
batteries are good
b (T90, T110VDE) is NOT on
B (T130VDE, T150VDE) does not show in
the display
3. Continue to hold the probe tips together for more
than three seconds.
4. Open the probe tips again. All LEDs (all but z
and g) must be on and all symbols in the LCD
(T130VDE, T150VDE) show for one second. This
test makes sure that all other internal circuits and
indicators are good.
5. Measure a known voltage such as a 230 V socket
outlet. This completes the self-test and includes
the >ELV circuit.
If the Tester fails the self-test or voltage test, do not
use. See “Contacting Fluke” for servicing.
For an inspection of the insulation, cables, and case,
see Safety Information.