323/324/325 Clamp Meter Users Manual PN 4045153 May 2012 © 2012 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names are trademarks of their respective companies.
LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for two years from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf.
Table of Contents Title Page Introduction ................................................................................................................. 1 How to Contact Fluke ................................................................................................. 1 Safety Information ...................................................................................................... 2 How to Clean the Product ..................................................................................
323/324/325 Users Manual ii
Introduction The Fluke 323/324/325 Clamp Meters (the Product) measure ac and dc voltage, ac current, resistance, and continuity. The 324 and 325 can also measure capacitance and contact temperature. The 325 can also measure dc current and frequency. Note that the 325 is shown in all of the illustrations. For temperature measurement, you must use the included K-Type Thermocouple. XWWarning Read "Safety Information" before you use the Product.
323/324/325 Users Manual • Japan: +81-3-3434-0181 • Singapore: +65-6799-5566 • Anywhere in the world: +1-425-446-5500 Or, visit Fluke's website at www.fluke.com. To register your product, visit http://register.fluke.com. To see, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. Safety Information A Warning identifies conditions and procedures that are dangerous to the user.
Clamp Meter Safety Information To prevent possible electrical shock, fire, or personal injury: • Use only correct measurement category (CAT), voltage, and amperage rated probes, test leads, and adapters for the measurement. • Do not touch voltages > 30 V ac rms, 42 V ac peak, or 60 V dc. • Carefully read all instructions. • Hold the Product behind the tactile barrier. See The Clamp Meter, item .
323/324/325 Users Manual 4 • Comply with local and national safety codes. Use personal protective equipment (approved rubber gloves, face protection, and flameresistant clothes) to prevent shock and arc blast injury where hazardous live conductors are exposed. • Replace the batteries when the low battery indicator shows to prevent incorrect measurements. • The battery door must be closed and locked before you operate the Product.
Clamp Meter Safety Information • Connect the common test lead before the live test lead and remove the live test lead before the common test lead. • Remove all probes, test leads, and accessories before the battery door is opened. • Do not use and disable the Product if it is damaged. • Do not use the Product if it operates incorrectly. • Do not use test leads if they are damaged. Examine the test leads for damaged insulation, exposed metal. Check test lead continuity.
323/324/325 Users Manual • Remove batteries to prevent battery leakage and damage to the Product if it is not used for an extended period. • Remove batteries to prevent battery leakage and damage to the Product if is to be stored above its operating temperature. WCaution To avoid possible damage to the Product or to equipment under test, use a thermocouple rated for the temperatures to be measured. The Product is rated for -10.0 °C to +400.0 °C and 14 °F to 752 °F.
Clamp Meter Safety Information Table 1. Symbols Symbol Meaning AC (Alternating Current) Symbol Meaning J Earth ground DC (Direct Current) ~ Do not dispose of this product as unsorted municipal waste. Go to Fluke’s website for recycling information. AC and DC Current P Conforms to European Union directives. W Risk of Danger. Important information. See Manual. T Double insulated X Hazardous voltage. Risk of electric shock. Conforms to relevant Australian standards.
323/324/325 Users Manual Table 1. Symbols (cont.) Symbol M CAT III Meaning Battery CAT III equipment is designed to protect against transients in equipment in fixed equipment installations, such as distribution panels, feeders and short branch circuits, and lighting systems in large buildings. Symbol Meaning , Application around and removal from HAZARDOUS LIVE conductors is permitted.
Clamp Meter How to Clean the Product How to Clean the Product Regularly wipe the case with a damp cloth and weak detergent. W Caution To prevent damage to the Product, do not use abrasives or solvents to clean the Product case. To clean the Product Jaw: 1. Examine the jaw mating surface to make sure it is clean. If there is unwanted material (including rust), jaw closure will not be correct and there will be measurement errors. 2. Open the jaws and clean the clamp metal ends with a lightly oiled cloth.
323/324/325 Users Manual Specifications Electrical Specifications AC Current (Jaw) Range 323 ..................................................... 400.0 A 324, 325 ............................................. (40.00, 400.0) A Resolution 323 ..................................................... 0.1 A 324, 325 ............................................. (0.01, 0.1) A Accuracy ................................................ 2.0 % ±5 digits (45 – 65 Hz) 2.
Clamp Meter Specifications DC Voltage Range .................................................... 600.0 V Resolution ............................................... 0.1 V Accuracy ................................................. 1 % ± 5 digits Resistance Range 323, 324 ............................................. (400.0, 4000) Ω 325 ..................................................... (400.0, 4000, 40000) Ω Resolution ............................................... (0.1, 1, 10) Ω Accuracy ................
323/324/325 Users Manual Resolution ............................................... 0.1 Hz Accuracy ................................................. 0.5 % ±4 digits Trigger Level ........................................... 5 to 10 Hz, ≥10 A 10 to 100 Hz, ≥5 A 100 to 500 Hz, ≥10 A Contact Temperature (324, 325) Range...................................................... -10.0 °C to 400.0 °C Resolution ............................................... 0.1 °C Accuracy ...........................................
Clamp Meter Specifications Operating Humidity ................................. Non Condensing (≤10 °C) ≤90 % RH (at 10 °C to 30 °C) ≤75 % RH (at 30 °C to 40 °C) ≤45 % RH (at 40 °C to 50 °C) (Without Condensation) Operating Altitude ................................... 2000 meters Storage Altitude ...................................... 12,000 meters EMI, EMC ................................................ Meets all applicable requirements in EN/IEC 61326-1 Temperature Coefficients........................
CAT 600 V CAT 300 V 14 325 2 CAT CAT 600 V 300 V TRUE RMS CLAMP METER 323/324/325 Users Manual The Meter 1 gtq008.
Clamp Meter The Meter OFF 20 323 ON 324/325 ON MAXMIN k C FHz VA AC DC F gtq001.
323/324/325 Users Manual 2:00 MIN MAX ON 2:00 gtq002.
Clamp Meter The Meter CAT 600 V CAT 300 V CAT 600 V CAT 300 V 323, 324 325 325 TRUE RMS CLAMP METER 325 TRUE RMS CLAMP METER CAT CAT 600 V 300 V CAT CAT 600 V 300 V gtq003.
323/324/325 Users Manual 323 V dc 323 V ac - V V 324, 325 V dc & V ac - V or V >30 V CAT 300 V gtq004.
Clamp Meter The Meter CAT 600 V CAT 300 V CAT 600 V CAT 300 V 325 TRUE RMS CLAMP METER CAT CAT 600 V 300 V 325 TRUE RMS CLAMP METER CAT CAT 600 V 300 V 323 <70 324/325 <30 gtq005.
323/324/325 Users Manual HOLD 325 TRUE RMS CLAMP METER CAT CAT 600 V 300 V 20 V > 30 V AC/DC & ZERO ZERO ZERO ZERO AC/DC AC/DC AC/DC 2 sec gtq006.
Clamp Meter The Meter 324, 325 325 TRUE RMS CLAMP METER CAT CAT 600 V 300 V gtq009.
323/324/325 Users Manual AAA gtq007.