4 Fluke Calibration P3000 Series Hydraulic Deadweight Testers Models P3100 and P3200
Oil operated - single PCU
Model
P 3111- B A R 1 to 35 bar
P 3111- KG C M 2 1 to 35 kgf/cm
2
P 3111- PSI 10 to 500 psi
P 3111- K PA 100 to 3,500 kPa
P 3111- M PA 0.1 to 3.5 MPa
P 3112- B A R 4 to 140 bar
P 3112- K G C M 2 4 to 140 kgf/cm
2
P 3112- P S I 40 to 2,000 psi
P 3112- M PA 0.4 to 14 MPa
P 3113 - B A R 10 to 350 bar
P 3113 - K G C M 2 10 to 350 kgf/cm
2
P 3113 - P S I 100 to 5,000 psi
P3113-MPA 1 to 35 MPa
P 3114 - B A R 20 to 700 bar
P 3114 - K G C M 2 20 to 700 kgf/cm
2
P 3114 - P S I 200 to 10,000 psi
P 3114 - M PA 2 to 70 MPa
P 3115 - B A R 20 to 1,100 bar
P 3115 - K G C M 2 20 to 1,100 kgf/cm
2
P 3115 - P S I 200 to 16,000 psi
P 3115 - M PA 2 to 110 MPa
P 3116 - B A R 20 to 1,400 bar
P 3116 - K G C M 2 20 to 1,400 kgf/cm
2
P 3116 - P S I 200 to 20,000 psi
P 3116 - M PA 2 to 140 MPa
Water operated - single PCU
Model
P 3211- B A R 1 to 35 bar
P 3211- K G C M 2 1 to 35 kgf/cm
2
P 3211- P S I 10 to 500 psi
P 3211- K PA 100 to 3,500 kPa
P 3211- M PA 0.1 to 3.5 MPa
P3213-BAR 10 to 350 bar
P3213-KGCM2 10 to 350 kgf/cm
2
P3213-PSI 100 to 5,000 psi
P3213-MPA 1 to 35 MPa
P3214 -B AR 20 to 700 bar
P3214 -KGCM2 20 to 700 kgf/cm
2
P3214 -PSI 200 to 10,000 psi
P3214 -M PA 2 to 70 MPa
Water operated - dual PCU
Model
P3223-BAR 1 to 350 bar
P3223-KGCM2 1 to 350 kgf/cm
2
P3223-PSI 10 to 5,000 psi
P3223-MPA 0.1 to 35 MPa
P3224-BAR 1 to 700 bar
P3224-KGCM2 1 to 700 kgf/cm
2
P3224-PSI 10 to 10,000 psi
P3224-MPA 0.1 to 70 MPa
Ordering information
Options
A. Improved Accuracy Option
with Software - PressCal
Software is a Windows based
software program that allows
users to easily apply all neces-
sary corrections, allowing for
improved accuracy of 0.008%.
PressCal is provided as standard
with all 0.008 % instruments.
B. Fine Increment Weights
- Additional small weights
that allow for finer pressure
increments
PPA9159-CAL For use with
kPa, MPa, bar, or kgf/cm
2
weight sets
PPA9608-CAL For use with psi
weight sets
C. Conversion Weights - Allows
for an instrument to be used in
a pressure unit other than the
pressure unit the instrument
was ordered for.
Oil operated - dual PCU
Model
P3123-BAR 1 to 350 bar
P3123-KGCM2 1 to 350 kgf/cm
2
P3123-PSI 10 to 5,000 psi
P3123-MPA 0.1 to 35 MPa
P3124-BA R 1 to 700 bar
P3124-KGCM2 1 to 700 kgf/cm
2
P3124-PSI 10 to 10,000 psi
P3124-MPA 0.1 to 70 MPa
P3125-BAR 1 to 1,100 bar
P3125-KGCM2 1 to 1,100 kgf/cm
2
P3125-PSI 10 to 16,000 psi
P3125-MPA 0.1 to 110 MPa
P3125XT-BAR 1 to 1,200 bar
P3125XT-KGCM2 1 to 1,200 kgf/cm
2
P3125XT-MPA 1 to 120 MPa
Fluke Calibration
PO Box 9090,
Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (877) 355-3225 or Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or Fax (905) 890-6866
From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116
Web access: http://www.flukecal.com
©2011-2013 Fluke Calibration. Specifications subject to change without notice.
Printed in U.S.A. 6/2013 3633536C_EN Pub-ID 11745-eng
Modification of this document is not permitted without written permission
from Fluke Calibration.