Item Brochure

525B Temperature/Pressure Calibrator Fluke Calibration 3
General Specifications
Warm up time................................................................Twice the time since last warmed up, to a maximum of 30 minutes.
Settling time..................................................................Less than 5 seconds for all functions and ranges except as noted.
Standard interface.......................................................RS-232, IEEE-488 (GPIB)
Temperature performance
Operating ....................................................................0 °C to 50 °C
Calibration (tcal) ........................................................18 °C to 28 °C
Storage ........................................................................-20 °C to 70 °C
Electromagnetic compatibility..................................CE: Conforms to EN61326
Temperature coefficient.............................................Temperature coefficient for temperatures outside tcal ± 5 °C is
10 % of the 90 day specification (or 1 year if applicable) per °C
Relative humidity
Operating ....................................................................< 80 % to 30 °C, < 70 % to 40 °C, < 40 % to 50 °C
Storage ........................................................................< 95 % noncondensing
Altitude
Operating ....................................................................3,050 m (10,000 ft) maximum
Nonoperating..............................................................12,200 m (40,000 ft) maximum
Safety...............................................................................EN 61010 Second, ANSI/ISA-S82.01-1994,
CAN/CSA-C22.2 No. 1010.1-92, NRTL
Analog low isolation....................................................20 V
Line power
Line Voltage (selectable) ..........................................00 V/120 V or 220 V/240 V
Line Frequency ..........................................................47 to 63 Hz
Line Voltage Variation ..............................................± 10 % about line voltage setting
Power consumption.....................................................15 VA maximum
Dimensions
Height..........................................................................13.3 cm (5.25 in) plus 1.5 cm (0.6 in) four feet on bottom
Width.......................................................................... standard rack width
Depth...........................................................................47.3 cm (18.6 in) overall
Weight (without options)..............................................4 kg (9 lb)
Electrical Specifications
DC Voltage Specifications, Output
Absolute Uncertainty,
tcal ±
5 °C
±
(ppm of output + µV)
Stability
Ranges
[1]
90 days 1 year
24 hours, ±
1 °C
±
(ppm of output + µV)
Resolution
Maximum
Burden
[2]
0 to 100.000 mV 25 3303 5 + 2 1 µV 10 mA
0 to 1.00000 V 25 10 30 10 4 + 10 10 µV10 mA
0 to 10.0000 V 25 10030100 4 + 100 100 µV 10 mA
0 to 100.000 V 25 1 mV 30 1 mV 5 + 1 mV 1 mV 1 mA
TC Output
-10 to 75.000 mV 25 3303 5 + 21µV10
Notes:
[1] All outputs are positive only.
[2] Remote sensing is not provided. Output resistance is < 1.
Noise
Ranges
Bandwidth 0.1 to 10 Hz
±
(ppm of output + µV p-p)
Bandwidth 10 Hz to 10 kHz
(µV rms)
0 to 100.000 mV 1 µ
V6
µV
0 to 1.00000 V 10 µ
V6
0 µV
0 to 10.0000 V 100 µ
V6
00 µV
0 to 100.000 V 10 ppm+1 mV 20 mV
DC Current Specifications, Output
Absolute Uncertainty
tcal ± 5 °C ± (ppm of output + µA)
Ranges
[1]
90 days 1 year
Resolution
Maximum
Compliance
Voltage
Maximum
Inductive Load
0 to 100.000 mA 40 1501 1 μA 12 V 100 mH
Note:
[1] All outputs are positive only.
Noise
Ranges
Bandwidth
0.1 to 10 Hz p-p
Bandwidth
10 Hz to 10 kHz rms
0 to 100.000 mA 2000 nA 20 μA
Resistance Specifications, Output
Absolute Uncertainty
tcal ± 5°C, ±
Ω
Ranges
[1]
90 days 1 year
Resolution Allowable Current
[2]
5 to 400.00 Ω 0.012 0.015 0.001 Ω 1 to 3 mA
5 to 4.0000 kΩ 0.25 0.3 0.01 Ω 100 μA to 1 mA
Notes:
[1] Continuously variable from 0 to 4 kΩ.
[2] For currents lower than shown, the floor adder increases by Floor
(new)
= Floor
(old)
x I
min
/I
actual
.
For example, a 500 μA stimulus measuring 100 Ω has a floor uncertainty of 0.015 Ω x 1 mA/500 μA = 0.03 Ω.
Resistance Specifications, Input
Absolute Uncertainty
tcal ± 5°C, ± (ppm of output + Ω)
Ranges
[1]
90 days 1 year
Resolution Stimulus Current
5 to 400.00 Ω 20 0.0035 20 0.004 0.001 Ω 1mA
5 to 4.00000 kΩ 20 0.0035 20 0.004 0.01 Ω 0.1 mA
Note:
[1] 4-wire mode.