Specifications
Electrical Measurements27
27-11
POWER
Line power Switchable 115V, 230V adapter with country specific plug
Power Adapter
input voltage
15 ... 23 V dc; Use only Power Adapter BC430
Battery power Rechargeable Li-ion battery BP290 (installed)
Battery operating time
BP290 (standard
battery)
6.5 hours @ normal backlight
8 hours @ dimmed backlight
10.5 hours with display off
Charging time BP290 2.5 hours to 95 % (Analyzer off)
Battery operating time
BP291 (optional
battery)
13 hours @ normal backlight
16 hours @ dimmed backlight
21 hours with display off
Charging time BP291 5 hours to 95 % (Analyzer off)
Battery save Adjustable time for dimmed backlight
INTERFACES
USB USB 2.0 slave port. Max speed 460 k. Mini-USB input connector.
RS-232 Interface Use special adapter cable DB-9 to Mini-USB to connect GPS430 Time
Synchronization Unit.
Baudrate 1200 ... 430 kb/s (No split baudrate available, receive and transmit baudrates
are equal. Default baudrate is 115200.)
Stop bits 1
Data bits 8
Parity No
Transmission mode Asynchronous, full duplex
Handshake Xon Xoff (Software handshake only)
STANDARDS
Measurement methods
used
IEC61000-4-30 2
nd
edition class A
Measurement
performance
Fluke 435-II/437-II IEC61000-4-30 Class A, Fluke 434-II IEC61000-4-30
Class S
Power Quality EN50160
Flicker IEC 61000-4-15
Harmonics IEC 61000-4-7
Shipboard V/A/Hz MIL-STD-1399-300B