368/369 AC Leakage Current Clamp PN 4635451 November 2015 © 2015 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.
LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf.
Table of Contents Title Page Introduction ................................................................................................................. How to Contact Fluke ................................................................................................. Safety Information ...................................................................................................... Product Overview ................................................................................................
368/369 Users Manual ii
Introduction The 368/369 AC Leakage Current Clamp (the Product) is a handheld tool for measurement of ac leakage current. Principle of Leakage Current Measurement Based on the electromagnetic induction principle, the Product has a ring-shape current transformer comprised of a metal core and coil winding. The current transformer senses the magnetic field produced by the current or by the vector sum of the currents flowing in the conductor under test.
368/369 Users Manual How to Contact Fluke To contact Fluke, call one of the following telephone numbers: • Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) • Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853) • Canada: 1-800-36-FLUKE (1-800-363-5853) • Europe: +31 402-675-200 • Japan: +81-3-6714-3114 • Singapore: +65-6799-5566 • Anywhere in the world: +1-425-446-5500 Or, visit Fluke's website at www.fluke.com. To register your product, visit http://register.fluke.com.
AC Leakage Current Clamp Safety Information Safety Information A Warning identifies hazardous conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that can cause damage to the Product or the equipment under test. XW Warning To prevent possible electrical shock, fire, or personal injury: • Carefully read all instructions. • Read all safety Information before you use the Product.
368/369 Users Manual 4 • Do not use the Product if it operates incorrectly. • Comply with local and national safety codes. Use personal protective equipment (approved rubber gloves, face protection, and flame-resistant clothes) to prevent shock and arc blast injury where hazardous live conductors are exposed. • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc. • Limit operation to the specified measurement category, voltage, or amperage ratings.
AC Leakage Current Clamp Safety Information • Use only specified replacement parts. • Have an approved technician repair the Product. For safe operation of the Product, do not operate within external low frequency magnetic fields >100 A/m. WCaution To avoid damage to the Product: • Do not subject the jaw to unreasonably strong shock, vibration, or force. • If dust gets into the top of the jaws, remove it immediately.
368/369 Users Manual Table 1 is a list of symbols used on the Product or in this manual. Table 1. Symbols 6 W WARNING. RISK OF DANGER. X WARNING. HAZARDOUS VOLTAGE. Risk of electric shock. Consult user documentation. T Double Insulated , Application around and removal from uninsulated hazardous live conductors is permitted. Ñ Do not operate within external low frequency magnetic fields >100A/m.
AC Leakage Current Clamp Safety Information Table 1. Symbols (cont.) Battery P Conforms to European Union directives. ) Certified by CSA Group to North American safety standards. Conforms to relevant Australian EMC standards. Ã Conforms to relevant South Korean EMC Standards. ~ This product complies with the WEEE Directive marking requirements. The affixed label indicates that you must not discard this electrical/electronic product in domestic household waste.
368/369 Users Manual Product Overview Table 2 and Figure 1 explain the Product features. Table 2. Features 8 Keep fingers below the Tactile Barrier. Push to retain the measured data on the display. When pushed, shows on the display. When pushed again, data hold is canceled and disappears. The display shows the measured value (digital reading), unit, function, and lowbattery symbol. Push to choose the range of ac current (either mA or A).
AC Leakage Current Clamp Product Overview Table 2. Features (cont.) Push to turn on the display backlight. Push and hold for 2 seconds to turn on the spotlight. See Spotlight. Push to turn on or turns off the Product. Jaw trigger Push the jaw lock button and the trigger together to unlock the jaw. Spotlight. See Spotlight. Jaw Battery Housing holds the batteries. See Batteries.
368/369 Users Manual 1 11 2 3 4 10 7 9 6 5 12 8 hyz002.eps Figure 1.
AC Leakage Current Clamp The Display The Display Table 3 and Figure 2 explain the Product display. Table 3. Display Battery Symbol Main display The Product is searching for ranges. Fluke Connect is on. (Available in 368 FC and 369 FC only.) Min, Max, or Avg reading is showing. MinMax mode is active. Hold mode is active. Filter is active and filters signals from 40 Hz – 70 Hz. mA AC or A AC Remaining memory (Available in 368 FC and 369 FC only.
368/369 Users Manual 5 6 7 8 4 9 3 2 10 1 11 hyz001.eps Figure 2.
AC Leakage Current Clamp Clean the Product Clean the Product Periodically wipe the case with a damp cloth and mild detergent. W Caution To avoid damaging the Product, do not use abrasives or solvents to clean the Product. 1. Inspect the jaw mating surface for cleanliness. If any foreign material is present, the jaw will not close properly and measurement errors will result. 2. Open the jaws and clean the clamp metal ends with a lightly oiled cloth.
368/369 Users Manual Replacement Parts Replacement parts are listed in Table 4. To order, see How to Contact Fluke. Table 4.
AC Leakage Current Clamp Specifications Specifications General Measurement functions ........................ AC current Display (LCD) ........................................ Digital reading: 3300 counts, LCD refresh rate 4 times/sec Range selection .................................... mA/A: manual selection 3 mA/30 mA/300 mA: auto selection 3 A/30 A/60 A: auto selection Battery Type .................................................... 2 AA, IEC LR6, NEDA 15A, alkaline Life ...............................
368/369 Users Manual Weight 369 ...................................................... 600 g 368 ...................................................... 500 g Electrical Specifications Reference Conditions ........................... 23 ±5 °C and 80 % RH maximum A AC Range ........................................... 3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A Frequency .............................................. 40 Hz to 1 KHz Crest Factor ...........................................
AC Leakage Current Clamp Specifications AC Current Measurement Accuracy is specified for 1 year after calibration. Accuracy is given as ±(% reading + digit) 368 Range 3 mA [1] Resolution 369 T.C./°C Outside Filter On Filter Off Filter On Filter Off (40 to 70 Hz) (40 to 1 kHz) (40 to 70 Hz) (40 to 1 kHz) 18 °C to 28 °C 0.001 mA 1+5 1+5 1.5+5 1.5+5 0.02+1 30 mA 0.01 mA 1+5 1+5 1.5+5 1.5+5 0.02+1 300 mA 0.1 mA 1+5 1+5 1.5+5 1.5+5 0.02+1 3A 0.001 A 1+5 1+5 1.5+5 1.5+5 0.
368/369 Users Manual Environmental Specifications Operating temperature ......................... -10 °C to +50 °C Storage temperature ............................. -40 °C to +60 °C Operating humidity (without condensation)......................... Non condensing (<10 °C) 90 % RH (10 °C to 30 °C) 75 % RH (30 °C to 40 °C) 45 % RH (40 °C to 50 °C) Ingress Protection ................................ IEC 60529: IP30 with jaw closed Operating Altitude ................................. 2,000 m Storage Altitude .
AC Leakage Current Clamp Specifications Class B: Equipment is suitable for use in domestic establishments and in establishments directly connected to a low voltage power supply network which supplies buildings used for domestic purposes. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. Korea (KCC) ...................................
368/369 Users Manual Product Functions Auto Power Off Backlight 2 Min 15 Min hyz003.
AC Leakage Current Clamp Specifications hyz004.
Measure Load 3 1 Load 368/369 Users Manual Single-Phase Two-Wire Circuit Load Grounding Wire Load 2 • Example of Load Current Measurement Single-Phase Three-Wire or Three-Phase Three-Wire Circuit Insert only one of the wires through the jaws. hyz005.
AC Leakage Current Clamp Specifications Spotlight hyz006.
368/369 Users Manual Batteries 2 + + 1 hyz007.