Manual Supplement Manual Title: Print Date: Revision/Date: 726 Users September 2005 Supplement Issue: Issue Date: Page Count: 7 7/15 8 This supplement contains information necessary to ensure the accuracy of the above manual. This manual is distributed as an electronic manual on the following CD-ROM: CD Title: CD Rev. & Date: CD PN: © 2007-2015 Fluke Corporation. All rights reserved.
726 Users Manual Supplement Change #1 On page 2, replace the Pulse row with the following: Pulse 1-100,000 Frequency Max 15 kHz 1-10,000 Frequency Range 2 CPM to 15 kHz On page 12, Table 4, replace the Description for Number with the following: Cycles through: Slow repeating 0 % - 100 % - 0 % ramp Configurable repeating 0 % - 100 % - 0% ramp Configurable repeating 0 % - 100 % - 0 % ramp in 25 % steps Used for the pulse train and totalizer functions.
Manual Supplement 726 Users Loop Indicator Memory Locations for Calibrator Setups HART Mode Indicator % Error Indicators Units Display Mode Indicator Low Battery Symbol Auto Ramp Figure 4.
726 Users Manual Supplement On page 14, under Configuration Menus, add the following under the last bullet: • Step time • Ramp time On page 15, under Shut Down Mode, replace numbered steps with the following: 1. 2. 3. 4. Press until SHUT DOWN appears on the display. Use and to increase or decrease the time. Use and to turn on and off. Press to save the setting. On page 16, under Hart Resistor ON/OFF, replace step 2 with the following: 2. Use or and to toggle ON and OFF.
Manual Supplement 726 Users Ramp Time Ramp Time sets the ramp time from 5 sec to 99 sec. 1. Press until RAMP TIME appears on the display. 2. Use and to set the ramp time. 3. Press to save the setting. On page 25, Table 6, add the following: Cu10 10 Ω Copper 0.0042 Ω/°C -100 to 250 On page 42, under Auto Ramping the Output, replace the 2nd and 3rd bullets with the following: • 0 % - 100 % - 0 % configurable time smooth ramp. Set ramp time using configuration menu.
726 Users Manual Supplement On page 62, change the Range entries for “Thermocouple in mV read” and “Thermocouple in mV source”: From: -10 °C to 75 °C To: -10 mV to 75 mV On page 63, under the RTD Accuacy (Read and Source) (ITRS-90) table, replace the CU10 row with the following: Cu10 -100.0 250.00 1.
Manual Supplement 726 Users Change #2, 57003 On page 5, add the following under Caution: Static Sensitive The 726 MEASURE/SOURCE terminals are ESD (electro-static discharge) sensitive to levels above ± 4 kV. The Calibrator can experience temporary loss of measurement or source functionality, which may require operator intervention to restore product function, or even cause permanent damage.
726 Users Manual Supplement On page 61, in the notes under Temperature, Thermocouples add: When in a 3 V/m radiated EM field ≤ 300 MHz, add 2 % of range for all TC types. Change #3 On page 54, Table 8: Change: 8 Test lead, red Test lead, black 688051 688066 1 1 8 Fluke-7XX Test Lead Set 3397308 1 To: Change #4, 67391, 171, 512 On page 7, under Table 2, add: Symbol Consult user documentation. Conforms to relevant Australian EMC standards.
Manual Supplement 726 Users On page 65, under General Specifications, replace the Safety section and add: Safety IEC 61010-1: Pollution Degree 2 Electromagnetic Compatibility (EMC) International IEC 61326-1: Portable Electromagnetic Environment CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.