Fluke 750 Series Documenting Process Calibrators: Work smarter. Work faster.
Fluke 750 Series Documenting Process Calibrators: Work Smarter. Work Faster. Whether you’re calibrating instruments, troubleshooting a problem or running routine maintenance, Fluke 750 Series process calibrators can help you get the job done faster. It does so many different tasks, so quickly and so well, it’s the only process calibrator you need to carry. • Multifunctional. Calibrate temperature, pressure, voltage, current, resistance, and frequency.
Fluke 750 Series Documenting Process Calibrators: Calibrators as versatile as you are. The Fluke 750 Calibrators, offered in two models, let you choose the right set of capabilities for your needs. • The Fluke 753 offers simultaneous source and measure capabilities for all common process parameters. Create and execute automated procedures and automatically capture the results results. The USB interface enables two-way communication with popular PC-based instrumentation management applications.
It’s easy to calibrate and maintain HART instrumentation with one powerful tool. + With the 754 DPC, you can: • Generate precision electrical, temperature, or pressure signals for analog stimulus or sensor simulation. • Simultaneously measure electrical, temperature, or pressure signals from transmitter output. • Determine type, manufacturer, model, tag ID by interrogating HART devices. • Read HART PV function and smart transmitter digital output while measuring analog mA output.
HART applications Fluke 754: The HART calibrator that is easy to use. • Common practice commands—provide functions that are common to many but not all field devices, for example read multiple variables, set damping time, or perform loop test • Device-specific commands—provide functions that are unique to a particular field device, for example sensor trim. The 754 supports these devices: Today’s 754 supports device-specific instructions for a variety of popular instruments.
Why use “smart” instrumentation? Like most process plants, your organization is probably facing the dual challenges of maximizing productivity while minimizing maintenance costs. “Smart” digital transmitters offer superior performance and reliability, while saving time and effort in maintenance and calibration. Manufacturers of field instruments have helped accelerate the changeover by offering smart transmitters at prices nearly as low as analog units.
Automatically record and document your work Fluke 750SW DPC/TRACK 2 software includes an instrumentation data-base that makes it easy to manage your instrumentation, create and schedule tests, load and unload the 753 or 754, print a variety of standard reports, and manage calibration data. Print standard reports automatically. The software assembles pre-formatted reports from your database files, saving time and reducing errors.
Measurement function specifications Confidence Interval: k =3 DC voltage measurement Range (full scale) 100.000 mV 3.00000 V 30.0000 V 300.00 V Accuracy (% of reading + floor) 1 year 2 years 0.02 % + 0.005 mV 0.03 % + 0.005 mV 0.02 % + 0.00005 V 0.03 % + 0.00005 V 0.02 % + 0.0005 V 0.03 % + 0.0005 V 0.05 % + 0.05 V 0.07 % + 0.05 V Temperature coefficient: (0.001 % reading + 0.0002 % range)/°C from -10 °C to 18 °C and 28 °C to 50 °C, 100.000 mV range: 0.001 % of reading + 0.
Temperature measurement and simulation specifications Confidence Interval: k =3 Temperature, Resistance Temperature Detectors1 Degrees or % of reading Type (α) Range °C 100 Ω Pt (385) 200 Ω Pt (385) 500 Ω Pt (385) 1000 Ω Pt (385) 100 Ω Pt (3916) 100 Ω Pt (3926) 10 Ω Cu (427) 120 Ω Ni (672) -200 to 100 100 to 800 -200 to 100 100 to 630 -200 to 100 100 to 630 -200 to 100 100 to 630 -200 to 100 100 to 630 -200 to 100 100 to 630 -100 to 260 -80 to 260 Measure °C2 1 year 2 years 0.07 °C 0.14 °C 0.02 % + 0.
Pressure specifications The Fluke family of 29 pressure modules: Covers virtually any pressure application including gage, differential, dual (compound), absolute, and vacuum. • Display pressure readings in any of ten different pressure units you specify in the calibrator setup. • Rugged urethane molded cases protect the modules from rough handling and harsh conditions. • Features internal temperature compensation from O °C to 50 °C for full-accuracy performance.
General specifications Data log function Measure functions: Voltage, current, resistance, frequency, temperature, pressure Reading rate: 1, 2, 5, 10, 20, 30, or 60 readings per minute Maximum record length: 8000 readings (7980 for 30 or 60 readings per minute) Ramp function Source functions: Voltage, current, resistance, frequency, temperature Rate: 4 steps/second Trip detect: Continuity* or voltage *Continuity detection not available when sourcing current Loop power function Voltage: 26 V Accuracy: 10 %,