Manual Supplement Manual Title: 87 V Ex Users Part Number: 2518115 Print Date: December 2005 Revision/Date: Supplement Issue: Issue Date: Page Count: 6 6/11 3 This supplement contains information necessary to ensure the accuracy of the above manual. © 2006-2011 Fluke Corporation. All rights reserved. Printed in the U.S.A.
Manual Supplement 87V Ex Users Change#1 On page 55, under, Maximum output values at the voltage input change: From: Co = 2.52 F To: Co = 2.52 μF Under, Maximum output values at the current-measuring inputs change: From: To: Co = 1000 F Co = 1000 μF Change #2, 39785 On page 52, under Electrical Characteristics of the Terminals, replace the Diode row with the following: G 1000 V rms < 7.9 V dc 3.000 V dc 1 1.
87V Ex Users Manual Supplement Change #3, 44008 On page 45, under General Specifications, Change: Relative Humidity: 0 % to 80 % (0 °C to 35 °C); 0 % to 70 % (35 °C to 50 °C) To: Relative Humidity: 0 % to 80 % (0 °C to 35 °C) On page 47, under DC Voltage, Resistance, and Conductance Function, add the following note: [3] Maximum of 60 % relative humidity or a maximum of 28 °C. Under Range, change the following: From: 6.000 MΩ 50.00 MΩ To: 6.000 MΩ[3] 50.00 MΩ[3] In the 60.
Manual Supplement 87V Ex Users Change #4, W2041055 On page 6, under EX-Certification Data, Ex-designation: ( II 2 G EEx ia IIC T4 Change: To : Ex-designation: ( II 2 G Ex ia IIC T4 Change #5, 55377 On page 7, in Table 1 remove the following: ® Inspected and licensed by TÜV Product Services. On page 45, under General Specifications, replace Safety with: Safety: Meets 1000V CAT III/600V CAT IV per ANSI/ISA-61010-1 (82.02.01):2004, UL 61010-1:2004, CAN/CSA C22.2 No. 61010-1-04, and EN/IEC 61010-1:2001.