Manual Supplement Manual Title: Part Number: Print Date: Revision/Date: 80 Series V Users Web-Only May 2004 2, 11/08 Supplement Issue: Issue Date: Page Count: 6 6/15 6 This supplement contains information necessary to ensure the accuracy of the above manual. © 2010-2015 Fluke Corporation. All rights reserved.
80 Series V Users Manual Supplement Change #1 On page 42, Table 9, replace the AC72 with: AC172 Alligator Clips for use with TL175 test lead set. Change #2, 55804, 62912, 64090, 509, 167 On page 2, under the Safety Information, delete the bullets and move the last sentence on page 5, prior to Table 1: Electrical symbols used on the Meter and in the manual are explained in Table 1.
Manual Supplement 80 Series V Users On page 5, replace Table 1 with: Table 1. Electrical Symbols AC (Alternating Current) DC (Direct Current) Fuse Hazardous voltage. Risk of electric shock. Conforms to European Union directives. Risk of Danger. Important information. See Manual. Conforms to relevant North American Association directives. Battery. Low battery when displayed. Double insulated Continuity test or continuity beeper tone.
80 Series V Users Manual Supplement On page 40, replace Table 8 with: Table 8. Replacement Parts (cont.) Item AC172 AC172 TL175 MP81 MP390-391 NA U5 CR6 S2 TM1 TM2 6/15 Description Qty. Alligator Clip, Black Alligator Clip, Red Test Lead Set Thermocouple Assembly, K-Type, Beaded, Molded Dual Banana Plug, Coiled Access Door Fastener Tiltstand LCD, 4.
Manual Supplement 80 Series V Users On page 41, replace Figure 12 with: MP8 MP5 MP81 MP31 Holster MP15 U5 J1-2 CR6 Tilt Stand S2 MP13 MP2 MP9 MP41 J3 F2 MP27-30 F1 Quick Reference Guide MP4 MP14 Safety Information BT2 H5-9 (5) MP6 MP10-11 H2-4 (3) BT1 MP22 MP390-391 aom015c.eps Figure 12.
80 Series V Users Manual Supplement On page 43, replace the General Specifications, with: General Specifications Maximum Voltage between any Terminal and Earth Ground: 1000 V rms Fuse Protection for mA or μA inputs: 0.44 A, 1000 V, IR 10 kA Fuse Protection for A input: 11 A, 1000 V, IR 17 kA Display: Digital: 6000 counts updates 4/sec; (Model 87 also has 19,999 counts in high-resolution mode). Analog Bargraph: 33 segments, updates 40/sec.
80 Series V Users Manual Supplement Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. Korea (KCC) ....................................... Class A Equipment (Industrial Broadcasting & Communication Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. USA (FCC) ......