User's Manual

Manual Supplement 88 V Users
2 4/13
On pages 66 & 67 in the Specifications, remove Electromagnetic Compatibility and Safety
and add:
Safety ......................................................... IEC 61010-1: 600 V CAT IV / 1000 V CAT III, Pollution Degree 2
Electromagnetic Environment ................. IEC 61326-1: Portable
Electromagnetic Compatibility ................ Applies to use in Korea only. Class A Equipment (Industrial Broadcasting &
Communication Equipment)
[1]
[1] This product meets requirements for industrial (Class A) electromagnetic wave
equipment and the seller or user should take notice of it. This equipment is intended
for use in business environments and is not to be used in homes.
In the Detailed Specifications, prior to Table 12, add:
All ranges, unless otherwise noted: In an RF field of 3 V/m total accuracy = specified accuracy + 20 counts, except
600 A dc range, total accuracy = specified accuracy + 60 counts and all ac ranges = specified accuracy + 70
counts. Temperature not specified.