Datasheet

Inrush Current Ranges Accuracy
Current ranges (selectable) 1 A, 5 A, 10 A, 50 A, 100 A, 500 A, 1000 A
Inrush times (selectable) l s, 5 s, 10 s, 50 s, 100 s, 5 min
Cursor readings A peak max at cursor 1 and cursor 2 ± 5 % of full scale
Time between cursors** 4 to 235 pixels ± (0.2 % + 2 pixels)
Scope, dual channel scope with measurement reading
Input impedance
Input 1 1 M/12 pF; with BB120: 20 pF ± 2 pF; with BB120 ± 3 pF
Input 2 1 M/10 pF; with BB120: 18 pF ± 2 pF; with BB120 ± 3 pF
Vertical
Voltage ranges 50 mV/div to 500V/div ± (1% + 2 pixels)
Vertical sensitivity, resolution 5 mV/div to 500V/div, 8 bit (256 levels)
Bandwidth input 1 (voltage) DC to 20 MHz at inputs, or with VPS40 probe (Opt);
1 MHz with TL24 Leads
Bandwidth input 2 (current) DC to 15 kHz at inputs
10 kHz with 80i-500s Current Clamp
Coupling DC, AC (10Hz (-3 dB)
Horizontal
TimeBase modes Normal, roll, single
TimeBase ranges 60 s/div to 20 ns/div ± (0.4 % + 1 pixel)
Sampling rate 25 MS/s
Record length 512 per channel
(min / max samples)
Trigger source Input 1 or Input 2 or Automatic selection
Trigger mode Automatic Connect-and-View™, Free Run,
Single Shot.
Connect-and-View™ Advanced automatic triggering that recognizes signal patterns and automatically
adjusts triggering, timebase and amplitude. Automatically displa
ys stable pictures
of complex and dynamic signals like motor drive and control signals.
Pre-trigger Up to 10 divisions
Measurement readings, Volts & Amps (DC, AC, AC + DCrms, Peak max, Peak min, Peak min / max ),
per channel selectable Frequency, Duty cycle + or - , Phase, Pulse Width + or -, Crest factor
Ohms, Diode, Continuity, Capacitance
Ohms 500.0
5.000 k
, 50.00 k
, 500.0 k, ± (0.6 % +5 counts)
5.000 M, 30.00 M
Diode voltage 0 to 3.000 V ± (2 % +5 counts)
Continuity, shorts > 1 ms Beeper on at < 30 ±5 ,
Capacitance 50.00 nF, 500.0 nF, 5.000 µF, 50.00 µF, ±(2 % +10 counts)
500.0 µF
Temperature*** -100.0 °C to 400.0 °C, ±(0.5 % +5 counts)
-200.0 °F to 800.0 °F
Max current, max open circuit volt. 0.5 mA, < 4 V (all functions above)
Memory
Number of screens 20
Optical Isolated Interface
To printer Supports HP LaserJet™, DeskJet, Epson FX/LQ and Postscript printers with
optional PAC91 Printer Adapter Cable
To PC FlukeView
®
Power Quality Analyzer software with PM9080 Interface
Adapter included
FlukeView
®
Power Quality Software
Hardware requirements PC or 100 % compatible with Windows
®
95, 98, Me, 2000, NT4.0.
** 1 pixel = inrush time/250
*** Requires optional temperature accessory
• Inrush current up to 500A with supplied
current probe
• Use cursors to measure inrush current timing
• Connect-and-View™ scope for quick
wa
veform displa
y
20MHz bandwidth with optional 10:1 voltage
probe. 15kHz on current channel with
optional current clamp
FlukeView
®
P
ower Quality Analy
zer software
(included)
• Capture measurement screens for
professional-looking reports
• Log readings to your computer disk drive
• Works with Windows word processing,
spreadsheet and analysis software
• Window
s 95 / 98 / Me / 2000 / NT 4.0