Datasheet

Fluke 199C Color ScopeMeter (200 MHz / 2.5 GS/s)
Fluke 199C/S Color ScopeMeter (200 MHz / 2.5 GS/s) + SCC190
Fluke 196C Color ScopeMeter (100 MHz / 1 GS/s)
Fluke 196C/S Color ScopeMeter (100 MHz / 1GS/s) + SCC190
Fluke 199B ScopeMeter (200 MHz / 2.5 GS/s)
Fluke 199B/S ScopeMeter (200 MHz / 2.5 GS/s) + SCC190
Fluke 196B ScopeMeter (100 MHz / 1 GS/s)
Fluke 196B/S ScopeMeter (100 MHz / 1 GS/s) + SCC190
Fluke 192B ScopeMeter (60 MHz / 500 MS/s)
Fluke 192B/S ScopeMeter (60 MHz / 500 MS/s) + SCC190
Fluke 124 Industrial ScopeMeter (40 MHz)
Fluke 124/S Industrial ScopeMeter (40 MHz) + SCC120 kit
Fluke 123 Industrial ScopeMeter (20 MHz)
Fluke 123/S Industrial ScopeMeter (20 MHz) + SCC120 kit
SCC190 FlukeView
®
Software + Cable + Case (190 Series)
SCC120 FlukeView
®
Software + Cable + Case (120 Series)
PM9080 Optically Isolated RS-232 adapter/cable
SW90W FlukeView
®
ScopeMeter Software for Windows
®
ScopeMeter test tools come standard with a complete accessory package including line voltage adapter and battery pack
(installed). ScopeMeter 190B and 190C Series come with probes, probe accessories and multimeter test leads.
SCC kit includes: Hard-shell carrying case, optically isolated RS-232 interface cable, and FlukeView
®
for Windows
®
software.
© Copyright 2004 Fluke Corporation
All rights reserved. Data subject to change without notice.
ScopeMeter and FlukeView are registered trademarks of Fluke
Corporation. Windows is a registered trademark of Microsoft
Corporation. Printed in the Netherlands. 03/2004.
Pub_ID: 10705-eng
Rev. 01
Selection Table
Color ScopeMeter ScopeMeter ScopeMeter
190C Series 190B Series 120 Series
Fluke 199C Fluke 196C Fluke 199B Fluke 196B Fluke 192B Fluke 124 Fluke 123
Bandwidth 200 MHz 100 MHz 200 MHz 100 MHz 60 MHz 40 MHz 20 MHz
Max. real time sample rate 2.5 GS/s 1 GS/s 2.5 GS/s 1 GS/s 500 MS/s 25 MS/s
Max. equivalent time sample rate - 2.5 GS/s 1.25 GS/s
Display 14.4 cm Full Color LCD 14.4 cm Monochrome LCD 10.2 cm Monochrome LCD
Digital Persistence Yes, gives analog oscilloscope like - -
waveform decay (user selectable)
Envelope mode Yes Yes Yes
Waveform Compare Visual Reference Visual Reference -
and Automatic ‘Pass / Fail’ testing
Max. record length
… in Scope mode: 3000 points per input channel, allowing for high time resolution signal analysis using zoom 512 min/max points per input
… in ScopeRecord mode: 27,500 points per input or more (5 ms/div…2 min/div.)
Number of inputs 2 plus external / DMM input, all isolated from each other and from ground 2
Number of digitizers 2 2
Independently floating Up to 1000 V between inputs, references and ground -
isolated inputs
Input sensitivity 2 mV/div. … 100 V/div. 5 mV/div. … 100 V/div. 5 mV/div. … 500 V/div.
Glitch capture Up to 3 ns using Pulse Width triggering; 40 ns
50 ns peak detect at 5 µs/div. to 1 min/div.
Timebase range in Scope mode 5 ns/div. to 2 min/div. 10 ns/div. … 10 ns/div. … 20 ns/div. …
2 min/div. 1 min/div. 1 min/div.
Trigger types Connect-and-View™, Free Run, Single Shot, Edge, Delay, Video Frame, Video Line Connect-and-View™, Free Run,
Selectable pulse width and External Single Shot, Edge, Video
Dual Slope trigger and Event trigger (n-cycle)
Scope Measurements 7 cursors measurements, 30 automatic measurements cursors + 26 automatic
Automatic Vrms and watts measurement on 26 automatic measurements
cursor limited part of waveform measurements
Waveform Mathematics A + B, A – B, A x B, A versus B (X-Y-mode, giving Lissajous diagrams) -
Frequency Spectrum (FFT)
Scope-Record Trigger modes Start on Trigger, Stop on Trigger -
Capture last 100 screens Automatic, with Replay capability -
Dual input TrendPlot Yes, with Cursors and Zoom Yes
Memory for screens/set-ups 10 screens and set-ups; 20 10
5 more memories are made available upon registration of the ScopeMeter
Memory for recordings Two, each can store 100 scope screens, a ScopeRecord or a TrendPlot
True RMS multimeter 5000 counts, Volts, Amps, Ohms, Continuity, Diode, Temp
Safety certified (EN61010-1) 1000 V CAT II / 600 V CAT III (instrument and included accessories) 600 V CAT III (instrument
and included accessories)
Battery (installed) 4 hr Ni-MH BP190 7 hr Ni-MH 5 hr Ni-Cd
Line power Adapter / battery-charger included
Size (cm) 25.6 x 16.9 x 6.4 cm 23.2 x 11.5 x 5.0 cm
Weight 2 kg 1.2 kg
PC and Printer interface Using optional Optically Isolated RS-232 adapter / cable
Warranty 3 years on main instrument, 1 year on the standard accessories
Fluke Corporation
P.O. Box 9090
Everett, WA USA 98206
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
For more information call:
In the U.S.A. (800) 443-5853
or Fax (425) 446 -5116
In Europe/M-East/Africa +31 (0)40 2 675 200
or Fax +31 (0)40 2 675 222
In Canada (905) 890-7600
or Fax (905) 890-6866
From other countries +1 (425) 446 -5500
or Fax +1 (425) 446 -5116
Visit us on the world wide web at:
http://www.fluke.com
Fluke (UK) Ltd.
52 Hurricane Way
Norwich
Norfolk
NR6 6JB
United Kingdom
Tel.: 0207 942 0700
Fax: 0207 942 0701
E-mail: industrial@uk.fluke.nl
Visit us on the world wide web at:
http://www.fluke.co.uk
Ordering Information