700G Series Pressure Gauge Users Manual November 2011 © 2011 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.
LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for three years from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf.
Table of Contents Title Page Introduction .................................................................................................................... 1 How to Contact Fluke ..................................................................................................... 1 Standard Equipment....................................................................................................... 2 Safety Information ................................................................................
700G Series Users Manual Set Damping ........................................................................................................ 7 Set Sample Rate .................................................................................................. 7 Set TARE ............................................................................................................. 7 Function Lock .......................................................................................................
List of Tables Table 1. 2. Title Page Symbols................................................................................................................................. 4 Display and Buttons ..............................................................................................................
700G Series Users Manual iv
List of Figures Figure 1. 2. Title Page The Product ........................................................................................................................... 5 Change the Batteries .............................................................................................................
700G Series Users Manual vi
Introduction How to Contact Fluke The 700G Series Pressure Gauges (the Product) are high-accuracy digital pressure test gauges. Accurate to 0.05 % FS, the Products can be used as a calibration reference, or in any application where high-accuracy pressure measurement is required.
700G Series Users Manual Standard Equipment • Read all safety Information before you use the Product. • Do not use the Product in damp or wet environments. The Product ships with: • Protective Cover • Three AA Batteries (installed) • NPT/metric Adapter Safety Information A Warning identifies conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that can cause damage to the Product or the equipment under test.
Pressure Gauge Safety Information Hazard Location Information/Approvals Ex Hazardous Areas An Ex-hazardous area as used in this manual refers to an area made hazardous by the potential presence of flammable or explosive vapors. These areas are also referred to as hazardous locations, see NFPA 70 Article 500. ) ( ® LR110460 Class I, Div. 2, Groups A-D II 3 G Ex nA IIB T6 KEMA 06ATEX0014 X Ta=–10 °C...
700G Series Users Manual Symbols Symbols used on the Product and in this manual are explained in Table 1. Table 1. Symbols Symbol 4 Meaning Symbol Meaning W Risk of danger. Important information. See manual. P Conforms to European Union directives. X Hazardous voltage. Risk of electrical shock. ) Conforms to relevant North American Safety Standards. f Pressure ~ Do not dispose of this product as unsorted municipal waste. Go to Fluke’s website for recycling information.
Pressure Gauge Display and Buttons Display and Buttons Table 2. Display and Buttons The Display and Buttons are shown in Figure 1. The Buttons are explained in Table 2. 2 Item Function Push to turn the Product on. Push again to turn it off. Zeros the display. In Configure Mode, push the button to move forward through the menus. 3 4 MIN MAX records minimum and maximum pressure values and saves them in memory. Push to show maximum (MAX) indication.
700G Series Users Manual Table 2. Display and Buttons (Cont) Item 6 Function Push to go to setup and configuration menus. Push to make a selection. When the Product is not in Configuration mode, push to turn on the backlight. Push again to turn off the backlight. NPT Connector Pressure Display Engineering Units Bargraph Operation The subsequent sections tell you how to operate the Product. Push to turn on the Product.
Pressure Gauge Operation Set Auto Off Set Sample Rate Auto Off can be set in 1-minute increments from 1 to 30 minutes or you can turn off the function for continuous Product operation. The Product is configured for 30 minutes. Push and to set the necessary interval. The “off” position is at the low end of the selections, less than 1 minute. This function finds how often pressure is sampled and the display is updated. Selections are 0.5, 1, 3, and 10 samples/second.
700G Series Users Manual Function Lock When set, access to each of the settable parameters above can be turned “off” to prevent unauthorized configuration changes. This is done with password protection in Supervisory mode. Push to access Supervisory mode or to go back to normal operation. Supervisory Mode If necessary, each user-configurable parameter can be edited when you receive the Product. Some parameters are locked and must be unlocked to configure them. Use Supervisory mode to do this.
Pressure Gauge Battery Life How to Set a Custom Engineering Unit or Scale The last menu selection in Supervisory mode is SET FACTR. You can set a multiplier factor from 0.001 to 100 to make a custom scale. The set factor is multiplied by the psi measured and the result is shown. Example: 40 psi is the equivalent of 1000 lbs of product in a tank. You want to show the product weight with a 100 psi gauge. If you set a factor of 25, 40 psi pressure would show as 1000 (40 x 25).
700G Series Users Manual How to Change the Batteries XWWarning To prevent possible electrical shock, fire, or personal injury, batteries must only be changed in an area known to be nonhazardous. Explosion hazard. To change the batteries, see Figure 2: 1. Use a Phillips screwdriver to loosen the captive screw on the battery door. 2. Remove the battery door. 3. Replace the three AA batteries. 4. Install the battery door again. 5. Tighten the captive screw. gsn002.eps Figure 2.
Pressure Gauge Accessories Accessories RS-232 Interface The Product includes an RS-232 interface. Remove the Product holster and the input jack is on the back of the Product. You can use serial communication to configure and calibrate the Product and move measurement data from the Product to a PC. An RS-232/USB cable is sold separately and includes 700G/TRACK Software. For specifications on the interface, see the Specifications section.
700G Series Users Manual Specifications Available Input Ranges See PI Ranges and Resolution for available ranges in psi plus equivalent ranges and resolution for all engineering units. Accuracy Positive Pressure ............................................................................ ±0.05 % FS Vacuum .......................................................................................... ±0.1 % FS Temperature Compensation ...........................................................
Pressure Gauge Specifications Mechanical Specifications Dimensions .................................................................................... 11.4 x 12.7 (cm), depth = 3.7 cm (4.5 x 5 (in), depth= 1.5 in) Pressure Connection ............................................................................. ¼ in NPT Male Housing .................................................................................. Cast ZNAL Display 5-1/2 Digits, 16.53 mm (0.
700G Series Users Manual PI Ranges and Resolution Model Number 700G04 700G05 700G06 700G27 700G07 700G08 700G29 700G30 700G31 Pressure Range 15 30 100 300 500 1000 3000 5000 10000 Vacuum Range -14 -14 -12 -12 -12 -14 -14 -14 -14 Burst Pressure 500 500 1000 2000 2000 10000 10000 10000 15000 Proof Pressure 60 60 200 600 1000 2000 6000 10000 15000 Engineering Unit Factor psi 1 15.000 30.000 100.00 300.00 500.00 1000.0 3000.0 5000.0 10000 bar 0.
Pressure Gauge Specifications kg/cm2 0.07030697 1.0546 2.1092 7.0307 21.092 35.153 70.307 210.92 351.53 703.07 mmHg @ 0°C 51.71507 775.73 1551.5 5171.5 15515 25858 51715 * * * inHg @ 0°C 2.03603 30.540 61.081 203.60 610.81 1018.0 2036.0 6108.1 10180 20360 cmH2O @ 4°C 70.3089 1054.6 2109.3 7030.9 21093 35154 70309 * * * cmH2O @ 20°C 70.4336 1056.5 2113.0 7043.4 21130 35217 70434 * * * mmH2O @ 4°C 703.
700G Series Users Manual ftH2O @ 4°C 2.306726 34.601 69.202 230.67 692.02 1153.4 2306.7 6920.2 11534 23067 ftH2O @ 20°C 2.310814 34.662 69.324 231.08 693.24 1155.4 2310.8 6932.4 11554 23108 ftH2O @ 60°F 2.308966 34.634 69.269 230.90 692.69 1154.5 2309.0 6926.9 11545 23090 ft Sea Water 2.24719101 33.708 67.416 224.72 674.16 1123.6 2247.2 6741.6 11236 22472 m Sea Water 0.68494382 10.274 20.548 68.494 205.48 342.47 684.94 2054.8 3424.7 6849.4 Torr 51.