Brochure

705/707/707Ex/715
Loop Calibrators
10034-eng Rev. 08
C12A (705/707) C25 (715) TL220 TP920 TPAK (715)
4-20 mA, source, measure, simulate
705 Loop Calibrator
Simultaneous mA and %
mA accuracy of 0.02%
Measure, source and simulate mA
Push button 25% steps for fast,
easy linearity checks
“Span Check” for fast confirmation of
zero and span
Selectable slow ramp, fast ramp,
and step function
24 volt internal loop supply
0 - 20 mA or 4 - 20 mA default
start up modes
707 Loop Calibrator
Features of the Fluke 705
“Quick Click” detented rotary knob for
one handed operation
Higher accuracy: 0.015%
Mains Voltage Input protection
250 Ohm loop resistance for with
Hart instrumentation
715 Volt/mA Calibrator
Measure loop current (0-20 mA, 4-20 mA)
signals with 0.015% accuracy and
0.001 mA resolution
Measure voltage output process signals
from PLCs, transmitters
Source or simulate 24 mA loop current
Source voltage to 100 mV or 10V
24V loop supply with simultaneous
current measurement
707Ex Intrinsically Safe Loop
Calibrator
Same features as Fluke 707
For use in explosion endangered areas
ATEX certified ( II 2 G Eex ia IIC T4)
Functions 705/707/707 Ex 715
Voltage measurement
Range 0-28 V DC 0-200 mV, 0-20 V
Resolution 1 mV 10 µV 1 mV
Accuracy 705: 0.025% Rdg + 2 LSD 0.01% Rdg + 2 LSD
707/707Ex: 0.015% Rdg + 2 LSD
Current measurement
Range 0-24 mA 0-24 mA
Resolution 0.001 mA 0.001 mA
Accuracy 705: 0.025% Rdg + 2 LSD 0.015%
707/707Ex: 0.015% Rdg + 2 LSD
Current sourcing
Range 0-20 mA or 4-20 mA
1
0-20 mA or 4-20 mA
1
Accuracy 705: 0.025% Rdg + 2 LSD 0.015% + 2 LSD
707/707Ex: 0.015% Rdg + 2 LSD
Drive capability 705: 1000 Ω @ 24 mA 1000 Ω @ 24 mA
707: 1200 Ω @ 24 mA
707Ex: 700 Ω @ 20 mA
Loop power while measuring mA 24 V 24 V
Voltage sourcing N/A 0-100 mV or 0-10 V
Display current and % of span Yes mA or %
Auto step, auto ramp Yes Yes
Span Check Yes Yes
Specifications
1
will over-range to 24 mA
Fluke 705, 707, 707Ex
Maximum voltage: 30 V (28 V - 707Ex)
Operating temperature: -10 to 55°C
Safety: CSA C22.2 No. 1010.1: 1992
EMC: EN50082-1:1992 and EN55022: 1994 Class B
Size (HxWxD): 164 mm x 75 mm x 47 mm;
Weight: 0.35 kg
Battery: One 9 V alkaline
Battery life: 18 hours typical, at 12 mA
Warranty: Three years (one year, 707Ex)
715
Size (HxWxD): 201 mm x 98 mm x 52 mm
Weight: 0.6 kg
Battery: One 9V alkaline
Battery life: 4 to 20 hours
Warranty: Three years
Included Accessories
Fluke 705/707: C10 Yellow Holster, TL75 Test
Leads, AC72 Alligator Clips, Single 9V alkaline
battery, Instruction Sheet
Fluke 707Ex: Red Ex-holster, Fluke TL75
Test Leads, AC72 Alligator Clips, Single 9V
alkaline battery, Instruction Sheet
Fluke 715: Yellow Holster (H80M excl. TPAK),
TL75 Test Leads and AC72 Alligator Clips,
Single 9V alkaline battery, Instruction Sheet
Ordering Information
Fluke 705 Loop Calibrator
Fluke 707 Loop Calibrator
Fluke 707Ex Intrinsically Safe Loop
Calibrator
Fluke 715 Volt/mA Calibrator
Fluke 705
Fluke 707
Fluke 715
Fluke 707Ex
Recommended Accessories
(Not for hazardous zones)